Threaded Entry

Side Flats

1.  Connect branch conduit connectors (By Others) 

to the junction box using either the threaded 

conduit entries on the bottom of the junction 

box or through holes drilled into the sides of the 

junction box. 

2.  Place housing in hole. Align junction box in the 

path of the conduit trench.

3.   Align holes to final installation orientation. Point 

arrows on temporary cover toward surface to 

be illuminated. 

 

 NOTE: Do not remove temporary cover until 

installation of faceplate.

Flush with finished grade

5.    Raise housing on EMT so housing is flush with 

finished grade. Use a level to aid in leveling 

housing. 

6.  When housing is level, tighten screws on 

Patented Stability Flange™ to secure housing to 

EMT. Remove excess EMT as needed.

Housing

4.  Insert (4) pieces of ½” EMT conduit through 

the Patented Stability Flange™. Hammer into 

substrate  until secure.

 Leave sufficient clearance to elevate housing 

to finished grade.

IMPORTANT SAFETY INFORMATION LISTED ON REVERSE

READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS

PROJECT:

TYPE:

DR

2

 SERIES

Deep Housing - Metal Halide (T6)

Remote Ballast Installation Instructions

Soil Prep

Conduit
trench

18”

Dia.

A.  Determine Soil Type by referencing DIG-IT 

Guide. 

B.  Dig hole 18” wide and 24” deep.

Conduit
Trench

Excavated 
for Housing

C.  Prep soil according to DIG-IT Guide.

Summary of Contents for Precision2 DR2 Series

Page 1: ...with correct wattage and type of lamp marked on fixture label All gaskets o rings and sealing surfaces must be kept clean during installation and service failure to do this may cause an unsafe condition and void product warranty INSTRUCTIONS PERTAINING TO A RISK OF FIRE OR INJURY TO PERSONS IMPORTANT SAFETY INSTRUCTIONS Lighted lamp is HOT WARNING To reduce the risk of FIRE OR INJURY TO PERSONS Tu...

Page 2: ...allation of faceplate Flush with finished grade 5 Raise housing on EMT so housing is flush with finished grade Use a level to aid in leveling housing 6 When housing is level tighten screws on Patented Stability Flange to secure housing to EMT Remove excess EMT as needed Housing 4 Insert 4 pieces of EMT conduit through the Patented Stability Flange Hammer into substrate until secure Leave sufficien...

Page 3: ...Barrier Plate clockwise to lock Patented HydroLock Barrier Plate must be completely seated to ensure proper seal or water may intrude This step must be done as stated or you will void your warranty 5 Connect optical assembly to Patented HydroLock Barrier Plate with quick disconnect IMPORTANT SAFETY INFORMATION LISTED ON REVERSE READ FOLLOW AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS PROJECT ...

Page 4: ...ool to install screws Do not exceed 40 in lbs DR2 SERIES Deep Housing Metal Halide T6 Remote Ballast Installation Instructions 6 Place optical assembly in housing resting the OptiLock on the pins provided inside the housing Align keyhole notch under one 1 of three 3 8 screw heads Tighten screw heads with Phillips screw driver Install proper T6 metal halide lamp 8 Install cutoff glare shield by squ...