Fixture Relamping

PROJECT:

TYPE:

RELEASE DATE

08/02/2021

REFERENCE NUMBER

INS-2826-00

40429 Brickyard Drive • Madera, CA 93636 • USA

559.438.5800 • FAX 559.438.5900 

www.bklighting.com • [email protected]

B-K LIGHTING

This product is available with field replaceable components. Exclusive interchangeable OPTIKITS and modular 

LED components with quick disconnects simplifies upgrades and maintenance when necessary.

IMPORTANT SAFETY INFORMATION LISTED ON REVERSE

READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION 

INSTRUCTIONS

5.   Remove retainer

4.   Twist and pull away optic.

10.  Connect new driver assembly to fixture leads. 

Place connections inside body cavity, then 

slide down fixture body along guides.

6.   Disconnect driver assembly from fixture body. 

 

7.  Separate heatsink from driver assembly via 

quick disconnect.

8.   Remove protective plastic from the double-

sided tape square on clean top of driver 

assembly. 

9.  Reconnect heatsink assembly to driver 

assembly via quick disconnect. Quick 

disconnect tucks into  space underneath 

heatsink. Press heatsink down along guides 

until flush and even with tape on driver.

11.   Reinstall Retainer

1.  Remove faceplate from collar using (2) #8-32 

faceplate screws with a 9/64” allen wrench.

2.  Remove fixture from collar.

3.  Loosen three (3) #8-32 set screws with a 

5/64” allen wrench to remove cap from fixture 

body.

     INTEGRAL DENALI SERIES UPLIGHT

Surface Mount Installation