RELEASE DATE
08/02/2021
REFERENCE NUMBER
INS-2826-00
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
INTEGRAL DENALI SERIES UPLIGHT
Surface Mount Installation
8. Remove temporary cover and pull out primary
120v, branch circuit wiring.
Finished grade
Wire nuts must
clear opening
6”
min.
9. Access primary 120v, branch circuit
wiring inside housing. Make watertight
connections using waterproof wire
connectors (by others). Wire connectors
must clear opening. Insert fixture, wiring
and connections into housing.
See wiring
diagram.
In-Ground Installation Instructions
10. Mount faceplate to collar using (2) #8-32 flat
head screws (provided) with a 9/64” allen
wrench.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION
INSTRUCTIONS
LINE
GROUND
GROUND
FIXTURE
COM
LINE
COM
Pull branch circuit wiring. Make watertight
connections from branch circuit wiring
to fixture leads using waterproof wire
connectors (by others) in splice location
as per NEC. UL Listed splice location
required. Connect incoming green ground
wire to ground wire from fixture.
See wiring
diagram.
WIRING DIAGRAM
All line voltage connections must be made
in compliance with the National Electrical
Code. Failure to do so will void warranty.