 2.  To  aim,  loosen  the  two  (2)  Phillips  screws 

attaching  the  adjustable  bracket  to  the 

faceplate. Aim to desired position. Tighten two 

(2) Phillips screws to lock in place when desired 

angle is set.  

Phase 2 - Finish Installation of Fixture with Remote Transformer

Phase 1 - Rough In

Installation of Back box

2.  Install  Conduit  (By  Others)  to  be  used  with 

this product. 

5.  Connect  box  to  conduit  and  pull  wires  for 

connections (See Wiring diagram).

Additional Info

•  Please follow National and Local electrical codes for your area. 
•  Suitable for through wire.
•  Suitable for installation into combustible materials.
•  Rated for 90° C.
•  Orientation  of  installed  back  box  determines  faceplate  screw 

orientation.

IMPORTANT SAFETY INFORMATION LISTED ON REVERSE

READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS

TECHNOLOGY

with

TECHNOLOGY

BACK BOX

Solid State LED

Installation Instructions

LINE

12V

Fixture

COM

Remote

Transformer

COM

WIRING DIAGRAM

 LED - For use with 12VAC 

remote 

transformer or magnetic transformers only. B-K 

Lighting  cannot  guarantee  performance  with 

third party manufacturers’ transformers.

3.  Mount faceplate using two (2) #10-24 screws with 

1/8”  Allen  wrench.  Tighten  evenly  to  compress 

gasket. Do not over tighten.

1.  Make  watertight  connections  from  remote 

transformer    to  LED  leads  using  waterproof  wire 

connectors. (By Others) 

See wiring diagram.

1.  Remove  canopy  and/or  fixture  from  MB2 

housing.  Ensure unused tapped holes are 

plugged to maintain seal. Plugs are provided.

3.  To  prepare  MB2  for  mounting,  align 

mounting  brackets  on  back  of  box.  Brackets 

can  be  aligned  to  vertical,  horizontal  or  45° 

orientation.    Secure  with  mounting  screw 

using screwdriver.

 

Install  back  box  so  that  front  face  is  flush 

with finished wall or ceiling. Make sure 

rectangular  back  box  is  plumb  before 

proceeding.

4.  Mount  MB2  box  to  surface  using  mounting 

hardware  (Provided)  using  the  mounting 

brackets attached to back of MB2 box.

 

Alternative mounting methods may 

compromise integrity of MB2 against water 

intrusion and will void warranty.

 

NOTE: Surface conduit is a common entrance 

for  water  if  not  properly  sealed.  Seal 

connector threads and conduit with a suitable 

sealant    (Teflon  tape,  adhesive,  etc.).  Sealing 

the conduit after knockouts are removed is 

required to maintain warranty.