background image

IMPORTANT SAFETY INFORMATION LISTED ON REVERSE

READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS

In-Ground Installation Instructions

RELEASE DATE

07/11/2023

40429 Brickyard Drive • Madera, CA 93636 • USA

559.438.5800 • FAX 559.438.5900 

www.bklighting.com • [email protected]

B-K LIGHTING

REFERENCE NUMBER

INS-2862-00

9.  Remove temporary cover and pull out remote 

wiring.

Finished grade

Wire nuts must 

clear opening

6” 

min.

10. Access remote wiring inside housing. Make 

watertight connections using waterproof wire 

connectors. Wire connectors must clear opening. 

Insert fixture, wiring and connections into housing. 

See wiring diagram.

HOT

12V

12V

FIXTURE

NEUTRAL

Remote

Transformer

WIRING DIAGRAM

 

LED - For use with 12VAC LED remote 

transformer or magnetic transformers only. B-K 

Lighting cannot guarantee performance with 

third party manufacturers’ transformers.

8.  Fill with soil, then compress. Layer paver sand as 

required for paver installation, then install pavers. 

Pavers may need to be cut to fit around housing.

11.  Mount faceplate to collar using two (2) #8-32 flat 

head screws (included) with a 9/64” allen wrench.

Stability Flange

Rebar or Stake (Not Included)

Pea Gravel

Finished Grade

Pavers

Paver Sand

Soil

Standard Installation

ARTISTAR UPLIGHT

SURFACE MOUNT