IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
In-Ground Installation Instructions
Soil Prep
RELEASE DATE
07/11/2023
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
REFERENCE NUMBER
INS-2862-00
Conduit
trench
B. Dig hole 10” wide and 10” deep.
Conduit
Trench
Excavated
for Housing
C. Prep soil according to DIG-IT Guide.
A. Determine Soil Type by referencing DIG-IT Guide.
Prep soil according to DIG-IT Guide.
Fixture Installation
5. Place Power Pipe in hole.
NOTE: Leave sufficient wire length in the power
pipe for future service.
6. Orient the arrows on the temporary cover to
the desired position of the final faceplate screw
placement.
NOTE: Do note remove temporary cover until
installation of faceplate.
7. Per DIG-IT Guide, backfill the gap between the
bottom of housing and bottom of hole with sand or
pea gravel for drainage.
NOTE: The mounting collar must be flush
to finished grade. Use stability flange to aid in
installation as shown.
Stability Flange
Rebar or Stake (Not Included)
Pea Gravel
Finished Grade
Pavers
Paver Sand
Soil
Screws on faceplate will
align with alignment
arrows on temporary
cover
1. Excavate trench according to designed lighting
plan 12” deep and 12” wide suitable for the fixture
housing.
2. Supply low voltage wiring necessary for installation.
3. Slide stability flange onto housing.
NOTE: Product is supplied with a stability flange
to anchor fixture and aid i
n installation.
4. Loop minimum of 6” of low voltage wire inside
housing to allow for fixture service. Place fixture in
hole.
NOTE:
Do not remove temporary cover!
Finished Grade
12”
Finished Grade
8 3/4”
LINE
12V
FIXTURE
COM
Remote
Transformer
COM
Screws on faceplate
will align with
alignment arrows on
temporary cover
Stability Flange
Rebar or Stake (Not Included)
Pea Gravel or Sand
Finished Grade
Concrete
Stability Flange
Rebar or Stake (Not Included)
Pea Gravel or Sand
Finished Grade
Concrete
Finished Grade
Concrete
Wire Nuts Must
Clear Opening
6”
min.
Finished Grade
12”
Standard Installation
ARTISTAR UPLIGHT
SURFACE MOUNT