background image

To  delete  any  individual  test  result  in
the memory press 

or 

button for

3 seconds.

To  delete  all  test  results  press 
buttons at the same time for 2 seconds
and then big dEL character will be dis-
played. Keep on pressing 

buttons

until  2  beeping  sounds  will  be  heared
and dEL disappears from the display.

Small  DEL  icon  will  be  shown  on  the
left-up  of  the  display.  Press 

or 

button  until  2  beeping  sounds  will  be
heared  and  the  test  result  disappears
from the display.

Press 

to  see  the  individual  test

results.

The  first  display  shows  the  latest  test
result. 

Press 

button  to  see  the  average

results. Small AVG icon will be shown on
the display (7d = 7 days average; 23n =
23 results taken for average calculation).

Omnitest

®

plus

saves up to 250 test results in built-in memory and

3 different average glucose levels are calculated and saved. These
values will appear on the display by recalling anytime you like to see
them. The latest result will replace the oldest beyond 250 data.

The meter enters “Memory” mode by pressing the 

button shortly.

Average results (AVG) can not be deleted, because they are calcula-
ted from the remaining test results in the memory.

31

Deleting Test Results

30

Reviewing Your Results

Summary of Contents for Omnitest plus

Page 1: ...Omnitest plus Blood Glucose Monitoring System www omnitest bbraun com ...

Page 2: ...diabetes care professional for the proper use of this meter and daily management of your diabetes Do not change your therapy due to blood glucose results of the Omnitest plus system without prior consulting your physician Warning 2 3 Important information Content Omnitest plus Blood Glucose Monitoring System 4 The Meter Display Segments 6 Quick Reference 8 Omnitest plus Blood Glucose Test Strip 12...

Page 3: ...y Omnitest plus Control control solution sold separately 4 Omnitest plus Blood Glucose Monitoring System Check your Omnitest plus system to contain all parts shown at the outer packaging If anything is missing please return your system to the place of purchase or contact your nearest B Braun representative ...

Page 4: ...e SET mark will display during ALL meter setting The CODE mark will display while coding the meter Test strip ejector Test strip port Product label Data transfer port LCD display Down button Power Select button Up button Battery cover Segment Meaning Segment Meaning AVG is displayed when average results are shown Control solution symbol Alarm symbol Buzzer symbol Sample applying symbol Test result...

Page 5: ...9 8 Quick Reference CODE 1 2 3 4 3 sec ...

Page 6: ...c b 11 10 Quick Reference 7 8 5 6 a e d f ...

Page 7: ...ual for Omnitest plus blood glucose test strip for additional information Note Opening of the measurement chamber Confirmation window Meter contacting leads Use test strip immediately after removing it from the vial Do not use test strips after the expiration date printed on the package or vial since it may cause inaccurate results Make a notation of the date on the vial label when you first open ...

Page 8: ... numbers match you can start testing If these two code numbers do not match you must code the meter according to the test strip vial code number 15 14 Code the Meter Without matching the code numbers you will not get accu rate test results of your blood glucose level Caution Press button to increase the code number or button to decrease the code number The number increases or decreases by one digi...

Page 9: ...con appears on the display or when the meter does not power on by any means The meter needs only one 3V Li CR2032 battery One battery is provided with the Omnitest plus meter system When changing battery pay attention to the polarity which is printed in the battery holder of the meter The plus of the bat tery has to face up If the new battery is inserted at first all segments of the display will b...

Page 10: ...ose test results are not consistent with your symptoms or if you think they are not accurate If you have dropped the meter For quality control in the point of care usage For teaching or learning the system To perform a control solution test follow the same test procedure as for a blood glucose test substituting control solution for the drop of blood For detail instruction see page 35 Testing Your ...

Page 11: ...nding the strip The me ter will turn on automatically Match the code number to the code printed on the test strip vial 1 Control Solution Test Mode When blood and test strip symbol appears press or button to mark the test as a control solution test in the meter memory Control solution symbol appears on the display If you decide not to do a control solution test press the or button again to remove ...

Page 12: ...sults fall outside the range repeat the test Out of range results may be caused by one or more of the following causes Error in performing the test Failure to shake the control solution vial gently Expired or contaminated control solution Control solution that is too warm or too cold Failure to discard the first drop of control solution and wipe the dispenser tip clean Contamination of the control...

Page 13: ...the Set the Meter mode at any time press the button for 3 seconds If you have missed out a setting start the Set the Meter procedu re again 1 2 3 4 5 6 7 25 24 Set the Meter There is no beep sound during buzzer is OFF when test strip is inserted and when test result pops up Note Set the Buzzer Turn on the meter by pressing button and hold for 3 seconds Buzzer icon will appear on the display Press ...

Page 14: ...sult Unit Press button to set the test result unit You should now be at the unit of measurement selection Select the proper unit of test result mg dL or mmol L for your blood glucose measurement by pressing the or button Set the Date and Time Press or button to select the year With the correct year on display press the button and the month setting will start fla shing Press or button to select the...

Page 15: ...aracter will display during the average day setting 1 First average 2 Second average 3 Third average setting setting setting Set the Alarm Omnitest plus has 5 different alarm settings The bell icon will be displayed during the alarm setting Alarm setting order is AL1 AL2 AL3 AL4 AL5 If the AL2 is OFF the rest of AL3 AL5 is all OFF Press or button to select the ON OFF of alarm function If you choos...

Page 16: ... results The first display shows the latest test result Press button to see the average results Small AVG icon will be shown on the display 7d 7 days average 23n 23 results taken for average calculation Omnitest plus saves up to 250 test results in built in memory and 3 different average glucose levels are calculated and saved These values will appear on the display by recalling anytime you like t...

Page 17: ... apart the spring tension increases When a click is felt the spring tension is locked and the device is ready for use Release the sliding barrel It will auto matically move back to its original position near the trigger hub Place Omnilance against the tip of the finger Next press the trigger and lift up the device It is less painful to prick you at the side of the finger tip Unscrew the Omnilance ...

Page 18: ...drop to form The flow of blood will be helped keeping the hand warm by lowering the hand to waist level and by gentle massage of the finger For safety reasons and to prevent crosscontamination discard the used lancet into an appropriate sharps or biohazard container Never allow another person to use a lancet that has already been used If the lancing device is to be used by another person the unit ...

Page 19: ...mmediately to prevent moisture from affecting the other strips Insert a test strip Push the test strip until it will go no further without bending the strip 1 If the code number on the display and on the test strip vial do not match do the Code the Meter procedure page 14 for accurate result If any different message appears on the dis play due to several causes and conditions please refer to Troub...

Page 20: ...inking reminds you to close the test strip vial cap immediately If you intend to change the code after 3 seconds have passed pull the test strip out of the port and re start the procedu re from the beginning Prick the area where you have decided to obtain the blood 3 Touch your finger to the tip of Omnitest plus test strip 4 39 38 Testing Your Blood Glucose ...

Page 21: ...insert the test strip Note The measurement chamber of the test strip will draw automatically the blood of your finger Your finger should remain still until the confirmation window is completely filled and you hear the beep sound The minimal sample volume is 1 L 5 Temperature infor mation and date information are alternatively dis played under the test result Accurate Results in Seconds After beep ...

Page 22: ...t to a proper place Clean the meter if necessary according to Maintain Your Blood Glucose Monitor System page 44 6 Blood glucose test results are displayed on the Omnitest plus meter as either milligrams of glucose per deciliter of blood mg dL or millimoles of glucose per liter of blood mmol L depending upon the test result unit selected see page 27 The Omnitest plus meter displays results between...

Page 23: ... that the meter is maintained with proper care 1 The meter should be cared after test and cleaned if neces sary with soft cloth or paper tissues Objects which had been in contact with blood bear the potential risk for transmitting an infectious disease If necessary alcohol swab can be used to wipe out dirt on the outer surface of the meter but che mical solution such as benzene or acetone MUST NOT...

Page 24: ...he symbol appeared on the display Repeat the test with new test strip Apply blood or control solution only after the symbol appears on the display The test result is higher than 600 mg dL 33 3 mmol L In case of doubt of blood test result check the meter with control solution With normal result re test with blood sample two or three times When HI message persists please consult a doctor for assista...

Page 25: ...ving your finger from the test strip during tes ting Conduct a control solution test or a check strip test There may be a problem with the test strip The codes of the meter and of the test strip vial do not match Re test with a new test strip Conduct a control solution test Re code the meter and re test The meter does not power on Test does not start after apply ing sample The result is doubtful M...

Page 26: ...cifications Reading Time 5 sec Memory Capacity 250 test results Operating Temperature 10 C 40 C 50 F 104 F Operating Humidity 10 90 Sample Type Fresh capillary whole blood Sample Volume 1 0 L Display Type LCD Size L x W x H 79 x 51 x 18 mm Weight including battery 41 g Power Supply 1 x 3V Li battery CR2032 Battery Life Running 3000 tests Batch code This product fulfills the requirements of Directi...

Page 27: ...mnitest plus The laboratory system used for calibration of the Omnitest plus sys tem is YSI 2300 STAT plus which is equipped with a glucose oxidase system You can transfer test results from the Omnitest plus meter to a com puter where the data can be further analyzed To make use of this featu re you need the Omnitest plus PC interface cable REF 9152806G and compatible software e g Diabass ISBN 3 9...

Page 28: ...2 40 2 5 45 3 0 54 3 3 60 3 9 70 4 0 72 4 4 80 4 7 85 5 0 90 5 5 100 6 0 108 6 1 110 7 0 126 7 2 130 7 5 135 7 8 140 8 0 145 8 9 160 9 0 162 9 4 170 10 0 180 10 5 190 11 0 196 11 1 200 12 0 216 12 5 225 13 9 250 15 0 270 16 0 288 16 6 300 17 0 306 18 0 325 19 0 342 20 0 360 20 8 375 22 2 400 23 0 414 24 0 432 25 0 450 26 4 475 27 7 500 30 0 540 33 3 600 6 7 120 0 55 10 ...

Page 29: ...arl Braun Straße 1 34212 Melsungen Germany Tel 49 0 5661 71 3399 Fax 49 0 5661 71 3550 www bbraun com www diabetes bbraun com If you have any questions about the use of the Omnitest plus system please contact your near est B Braun representative or go www omnitest bbraun com ...