INSTRUCTION MANUAL

 

 

TagTemp  

Temperature Data Logger 

 

 

 

Technical changes reserved

 

B+B Thermo-Technik GmbH | Heinrich-Hertz-Str. 4 | D-78166 Donaueschingen 

0141 0315-84         22.06.2016

 

Fon +49 771 83160 | Fax +49 771 831650 | [email protected] | bb-sensors.com 

7 / 14 

5.

 

Select  “Search  for  the  best  driver  in  these  locations”  and 

check

  “Search 

removable media”. Click “Next”. If installation files are not in a CD, check “Include 

this location in the search” and show the file path. 

6.

 

If a prompt warns you that it does not support Windows® XP or that signature 

verification failed, click “

Continue anyway

”. 

7.

 

The  interface  driver  files  will  be  copied  to  the  PC  and  after  a  few  seconds  a 
screen  is  displayed  informing  you  that  the  software  installation  has  been 

concluded. Click “Finish”. 

8.

 

In some situations, the steps described above may be repeated again. Follow the 
same procedures. 

In later uses of the interface, Windows® may require the driver installation again. In 

this case, the same installation wizard will be displayed, and you will have to select the option “Install software automatically 

(recommended), as the driver may already be in the computer. 

 

Logchart-II 

Software installation: 

 

Insert the supplied CD-ROM in the CD-drive of the PCs/Laptop.  

 

The software installlation wizzard will start automatically. If it does not, please run the 

LC_II_Setup.exe 

program

 

provided

 

from

 

your CD drive. To do so please follow the steps below: 

 

From the start menu of Windows run Windows Explorer. Choose the CD drive  

 

Double click on the icon 

LC_II_Setup.exe 

to run the setup

 

program. 

 

Follw the steps described in the Setup wizzard  

 

 

7.2 

Running LogChart_II 

When you open Logchart-II by double clicking on its icon the following main window is displayed 

Next, select the serial port that the communication interface will use in the “

Port

” menu. 

If using a serial port check which serial is available. Usually COM2 is free, once the mouse uses COM1. In the case of 

Ir-Link3/USB 

choose

 USB port. 

The chosen port will be chosen by default next times the LogChart II is initiated. When a valid port is selected, the 

buttons showed below are highlighted.  

 

 

 

 

Summary of Contents for TagTemp

Page 1: ...gTemp Temperature Data Logger Technical changes reserved B B Thermo Technik GmbH Heinrich Hertz Str 4 D 78166 Donaueschingen 0141 0315 84 22 06 2016 Fon 49 771 83160 Fax 49 771 831650 info bb sensors com bb sensors com 1 14 ...

Page 2: ...ADVICE 4 4 WASTE AND DISPOSAL ADVICE 4 5 USAGE ACCORDING TO PURPOSE 4 6 PRODUCT DESCRIPTION 5 1 1 Supply voltage 5 6 2 Unpacking 5 6 3 Identification 5 7 OPERATION 6 7 1 Drivers and software installation 6 7 2 Running LogChart_II 7 7 3 Configuring the logger 8 8 DATA TRANSFER AND VISUALISATION 10 8 4 Offloading data 10 8 5 Visualizing data 10 8 6 Chart view 10 8 7 Sheet view 12 8 8 General informa...

Page 3: ... service centers or your salesperson We go after giving you rapid and competent help to minimize the risk of long time outfalls The following operating Instruction are an indispensable part of of this Product It contains important advices for the starting up and further use of the device 2 GENERAL INFORMATION This documentation contains informations which must be paid in attention to assure a high...

Page 4: ... W21 Caution agaist mobile engines W29 Caution against moving parts Electronic waste 3 SECURITY ADVICE The B B Therm Thechnik GmbH assumes no liability for damages occurred through failure to observe these security advices A usage non conforme to the instructions given in this manual can damage the device Body and property damages The use of the measurement system must be restricted to qualified p...

Page 5: ...ata logger TagTemp is a highly autonome temperature measurement device It is supplied with a built in 3 6 V lithium battery CR2032 6 2 Unpacking The following items must be included in the package The electronic logger TagTemp A CD ROM with the Logchart II software and a USB driver Quick logger operation guide The present operating instructions Optional a communication interface upon request 6 3 I...

Page 6: ...30 seconds of user inactivity To reactivate it press again the Start Stop Button The logger operation mode set up is defined in advance by using the LogChart II software Each setting must be defined and the consequences observed The logger starts and stops logging as defined in settings 7 1 Drivers and software installation In the Ir Link3 RS232 model there is a RSR232 Ir communication interface I...

Page 7: ...e same installation wizard will be displayed and you will have to select the option Install software automatically recommended as the driver may already be in the computer Logchart II Software installation Insert the supplied CD ROM in the CD drive of the PCs Laptop The software installlation wizzard will start automatically If it does not please run the LC_II_Setup exe program provided from your ...

Page 8: ...wnload the actual contents of the logger s memory Press to view online the 10 last logged values 7 3 Configuring the logger Make sure the communication interface is connected to the PC port selected The interface must be constantly directed towards the communication window on front part of the logger at a maximum distance of 0 5 m The logger must be first woken up by pressing once the Start Stop S...

Page 9: ... 1 second and the maximum is eighteen 18 hours Note When the type of value logged is maximum or minimum values see Value the minimum interval possible is 10 seconds Daily Operations Here the user defines the time at which daily logs will take place Estimated time This field informs the user how long it will take to fill totally the memory under the conditions set up during configuration Start of r...

Page 10: ...tion the minimum interval between measurements Period is 10 seconds Offset Gives the user the possibility to automatically correct the values logged Alarm Defines limit values that when exceeded characterize an alarm condition Alarm events are informed to the user through a flashing mode of the Alarm Indicator LED After filling all the fields select OK and settings will be sent to the logger Note ...

Page 11: ...Temp Temperature Data Logger Technical changes reserved B B Thermo Technik GmbH Heinrich Hertz Str 4 D 78166 Donaueschingen 0141 0315 84 22 06 2016 Fon 49 771 83160 Fax 49 771 831650 info bb sensors com bb sensors com 11 14 ...

Page 12: ...lar form press the icon Table View Values are presented in a tabular form listing the measurement time and value 8 8 General information sheet This window shows some information about the logger whose data were just read and its configuration The screen can be displayed by pressing the Parameter Viewing icon 8 9 Exporting data Logged data can be exported to different file formats for further analy...

Page 13: ...s correctly selected there are no other programs using the same port during the communication attempts there is no physical obstacle blocking the IR signal the cable is well connected to the PC the port selected does not present any problem 10 MAINTENANCE The housing can be cleaned with a wet cloth Do not use chemical solvents With the exception of exchanging empty batteries the logger is widely m...

Page 14: ...ions 30 x 47 x 0 47 mm Logger PC data transfer time According to the number of logs 40 seconds for 16 000 logs PC Interface Ir USB or Ir Serial LogChart ll software operation environment Set up Software for Windows 95 98 NT 2000 and XP Menus in Portuguese English or Spanish Sets up reads and displays data on the screen TagTemp 0568 0037 Data Logger for the record of up to 16 000 temperature values...

Reviews: