Check to see if all external controls ie programmer or
room thermostat are calling for heat.
Resetting the Boiler
If a fault has occurred and the red LED is illuminated but
the pump continues to run, then switching the power off
for 30 seconds and then on again should reset the light.
This may be caused by the ambient temperature around
the boiler being too high. Check to ensure that any boiler
ventilation is not obstructed. If the fault reoccurs contact
your engineer.
IMPORTANT: Electrical safety checks should be
carried out by a qualified electrical engineer.
4
SIMPLE FAULT FINDING
If the boiler fails to start for no apparent reason make the
following checks before calling your service engineer.
Is green LED light illuminated?
No
Check for blown fuse or thrown power breaker. If
replacement fuse or power breaker fail again call service
engineer.
If the red LED is permanently illuminated contact your
service engineer.
Flashing red LED indicates an open circuit. The boiler
can still be operated. Service engineer should be
contacted.
1
2
3
4
3. TECHNICAL SPECIFICATION
AZTEC
AZTEC
AZTEC
AZTEC
AZTEC
MODEL
2 KW
6 KW
9 KW
11 KW
12 KW
ELECTRICAL
INPUT
2 KW
6 KW
9.15 KW
11 KW
12 KW
SUPPLY CURRENT (amp)
8.5A
25A
39A
45A
51A
RCD RATING
(amp)
13A
32A
40A
50A
63A
MINIMUM CABLE SIZE (mm)
1
4
6
10
16
WEIGHT (kg)
7.0
8.1
10.6
10.8
10.8
WATER CONTENT
(litres)
1.0
2.1
3.2
3.2
3.2
WIDTH (mm)
164
164
164
164
164
DEPTH (mm)
130
130
130
130
130
HEIGHT
(mm)
550
823
1073
1073
1073
MAINS SUPPLY
230V 50Hz
MAX OPERATING PRESSURE
3 bar
43.5 psi
TEST PRESSURE
6 bar
87 psi
BOILER FLOW TEMPERATURE - Adjustable between 50°C and 80°C
LIMIT THERMOSTAT - Factory set at 100°C
CASING FINISH - Stove enamelled white
THERMAL INSULATION - Insulated with mineral fibre