Adjusting the water temperature in the boiler.
The machines are equipped with a
single boiler, therefore the programmed temperature will be implemented in both the
espresso services as well as in the services of other soluble products.
The manufacturer recommends a temperature between 88 ° C and 92 ° C. Use the 461
function to program the temperature values.
Is important to avoid that the water exceeds its point of boiling. In cities to the level of
the sea the pressure is of 1 atmosphere and the temperature of boiling of the water is of
100 ° C, however, as increases the height decreases the pressure atmospheric and
decreases the temperature of boiling. Therefore, is important verify this factor in cities to
more than 1500mts on the level of the sea and avoid that the temperature of the water
in the boiler exceeds the temperature of boiling.
Verify that the dosage is correct whenever an adjustment is made and
perform a few coffee services to ensure proper operation.