background image

AB-7050 

 

Specifications/Instructions

 

Neosensor 

Room Temperature Sensor 

Room Humidity Sensor 

Room Temperature/Humidity Sensor 

 
General 

Neosensor is a series of electronic room sensors including 
temperature sensor (Models TY7043, TY7053), humidity 
sensor (Model HY7043), and temperature/humidity sensor 
(Model HTY7043).  Neosensor is coordinated in terms of 
design and dimension with Neostat electronic room 
temperature/humidity controller. 

Platinum resistance temperature detector for temperature 
sensing element and polymer capacitive detector (FP3

 

developed by Azbil Corporation) for humidity sensing 
element enhance accuracy and reliability of Neosensor 
sensing.  Neosensor is thus suitable for various applications 
such as commercial building air conditioning or other indoor 
uses. 

Note: 
*  The specification data of the two-wire 4-20mA output model of 

Neosensor is not included in this document.  Refer to the 
following document. 

 AB-7051 

Specifications/Instructions

:  

Neosensor (Two-Wire 4-20 mA Output Sensor)

 

Room Temperature Sensor (Model TY7043D),  
Room Humidity Sensor (Model HY7043D),  
Room Humidity/Temperature Sensor (Model HTY7043D) 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Features 

  Wide temperature and/or humidity sensing range with 

high accuracy. 

 

Excellent long-term stability. 

 High 

environmental 

resistance. 

 

 

Quick response and high repeatability. 

 

Compact (thin) and lightweight. 

 

CE Marking certified product: 
The following models conform to all the applicable 
standards of CE Marking. 
- Model TY7043Z0P0X 
- Model TY7053Z0P00 
- Model HY7043 series 
- Model HTY7043 series 

 

Summary of Contents for HTY7043T1P00

Page 1: ...sing Neosensor is thus suitable for various applications such as commercial building air conditioning or other indoor uses Note The specification data of the two wire 4 20mA output model of Neosensor...

Page 2: ...bligatory action to prevent possible danger The symbol inside graphically indicates the actual action to be carried out For example the sign on the left indicates general instructions CAUTION Use the...

Page 3: ...ow Available model numbers Model number Type Power Humidity output Temperature output Signal output wire connection Company logo HTY7043T1P00 Yes HTY7043T1P00 1 Neosensor 24 V DC AC 1 5 VDC RTD Pt100...

Page 4: ...iring Thermoplate for open wiring is used for open wiring installation Part No DY2000A3021 For mounting three Neosensor crosswise Auxiliary device Multi Thermocase Model TY1100Z LAN cable Part No DY72...

Page 5: ...tion resistance Min 500 V DC 20 M Withstand voltage 500 V AC applied for 1 min with max of 1 mA leakage current between housing and terminals Environmental conditions Rated operating condition Limit o...

Page 6: ...tead of lead wires Model TY7043Z0P01 1 Figure 1 Mounting dimensions mm Neosensor with Wall direct mounting kit Neosensor high sensitive type Note For wiring secure more than 15 mm clearance inside the...

Page 7: ...unting surface when installing Neosensor with Thermoplate mounting kit 2 The number of lead wires differs depending on the models Note that the Pt100 temperature sensor model with modular connection h...

Page 8: ...th Thermoplate mounting kit Figure 5 Mounting dimensions mm Neosensor high sensitive type with Thermoplate mounting kit on Thermoplate Thermoplate mounting kit Figure 6 Dimensions mm Mounting plate of...

Page 9: ...sensor model with modular connection has a modular jack instead of lead wires Model TY7043Z0P01 1 Figure 7 Mounting dimensions mm Neosensor not covered with Multi Thermocase mounting kit Multi Thermoc...

Page 10: ...rated by office device or equipment for example stays on Air circulation is interfered by furniture or door for example Temperature and or humidity sensing is affected by draft downdraft and hot cold...

Page 11: ...14 5 Set the depth change levers on the bilateral sides of the Neosensor main unit to the upper position indicated with L shown in Fig 17 6 Mount the main unit of Neosensor on the main unit of the Wa...

Page 12: ...d with L shown in Fig 17 6 Mount the main unit of Neosensor on the main unit of the Wall direct mounting kit with four mounting screws M3 16 supplied with Neosensor 7 Attach the cover back to the Neos...

Page 13: ...on the bilateral sides of the Neosensor main unit to the upper position indicated with L shown in Fig 17 7 Mount the main unit of Neosensor on the main unit of the Thermoplate mounting kit with four...

Page 14: ...lled with its cover removed IMPORTANT Before installing Neosensor in the Multi Thermocase be sure to set the depth change levers on the bilateral sides of the Neosensor main unit at the lower position...

Page 15: ...pth change Raising the Neosensor main unit 3 Set the depth change levers located on the bilateral sides on the main unit front surface at the lower position The levers are factory set at the upper pos...

Page 16: ...ck Blue Black 24 V AC DC 1 5 V DC 0 10 V DC Power supply Humidity Models HY7043T1000 1 and HY7043T6000 1 Figure 22 Terminal wiring Humidity sensor with 1 5V 0 10V humidity output 24 V AC DC power Pt10...

Page 17: ...sor temperature humidity sensor models IMPORTANT Use isolated transformer to supply 24 V AC power Single Neosensor must be powered by a single 24 V AC transformer If the multiple Neosensor or a Neosen...

Page 18: ...wing Use a controller with low pass filter 40 dB or higher removal ratio in normal mode that receives signals from Neosensor For insufficient removal ratio provide an isolator on the controller input...

Page 19: ...ration Neosensor is factory calibrated and does not require field calibration right after installation However field calibrate Neosensor if a shift in the output due to aged deterioration is found For...

Page 20: ...ademark of Azbil Corporation in Japan or in other countries Specifications are subject to change without notice Building Systems Company http www azbil com Rev 2 0 Sep 2015 AB 7050 J AI 7050 Rev 3 2 P...

Reviews: