Safety Precautions

Please read instructions carefully and use the product 

as specified in this manual. Be sure to keep this 

manual nearby for quick reference. 

Restrictions on Use

This product was developed, designed, and 

manufactured for general air conditioning use.
Do not use the product in a situation where human 

life may be at risk or for nuclear applications in 

radiation controlled areas. If you wish to use the 

product in a radiation controlled area, please 

contact Azbil Corporation.
Particularly when the product is used in the 

following applications where safety is required, 

implementation of fail-safe design, redundant 

design, regular maintenance, etc., should be 

considered in order to use the product safely and 

reliably. 
• Safety devices for protecting the human body
•  Start/stop control devices for transportation 

machines

• Aeronautical/aerospace machines 
For system design, application design, instructions 

for use, or product applications, please contact 

Azbil Corporation.
Azbil Corporation bears no responsibility for 

any  result,  or  lack  of  result,  deriving  from  the 

customer’s use of the product.

Recommended Design Life

It is recommended that this product be used within 

the recommended design life.
The recommended design life is the period during 

which you can use the product safely and reliably 

based on the design specifications. 
If the product is used beyond this period, its 

failure ratio may increase due to time-related 

deterioration of parts, etc. 
The recommended design life during which the 

product can operate reliably with the lowest failure 

ratio and least deterioration over time is estimated 

scientifically based on acceleration tests, 

endurance tests, etc., taking into consideration the 

operating environment, conditions, and frequency 

of use as basic parameters. 
The recommended design life of this product is 10 

years.
The recommended design life assumes that 

maintenance, such as replacement of the limited 

life parts, is carried out properly. 
Refer to the section on maintenance in this 

manual.

Warnings and Cautions

WARNING

Alerts users that improper handling 

may cause death or serious injury.

CAUTION

Alerts users that improper handling 

may cause minor injury or material 

loss.

Signs

Notifies users that specific actions are 

prohibited to prevent possible danger. 

The symbol inside 

 graphically indicates 

the  prohibited  action.  (For  example,  the 

sign on the left means that disassembly is 

prohibited.)

Instructs users to carry out a specific 

obligatory action to prevent possible danger. 

The symbol inside 

 graphically indicates the 

actual action to be carried out.  (For example, 

the sign on the left indicates general 

instructions.)

 

WARNING

When handling or transporting any heavy 

product  (more than 18 kg), carefully move 

the product with a handtruck or the like, or 

with 2 or more people.

Careless lifting or accidental dropping of 

the product may result in injury or product 

damage.

 

CAUTION

Provide a circuit protector  (e.g., a fuse or 

circuit breaker) for the power source.

Failure to do so may cause a short circuit 

leading to fire or device failure.

Do not freeze this product.

Doing so may damage the valve body and 

cause leakage.

When piping this product, be sure there is no 

foreign matter in the pipes.

If foreign matter remains in the pipes, the 

product may break down.

Install, wire, and use this product under the 

conditions specified by this manual.

Failure to do so may cause fire or device 

failure.

Use full face gaskets for flat face flanges.

Failure to do so may damage the flanges or 

cause leakage outside of the valve.

When installing this product, hold it in the proper 

position and securely fasten it to the pipes.

Excessive tightening or improper installation 

position may damage the valve.

Summary of Contents for ACTIVAL SCS13A

Page 1: ...mostat Model TY9800 4 20 mA DC input Provides proportional control in combination with a DDC controller e g Infilex GC Model WY5111 Model R35 R36 2 10 V DC input Provides proportional control in combi...

Page 2: ...equency of use as basic parameters The recommended design life of this product is 10 years The recommended design life assumes that maintenance such as replacement of the limited life parts is carried...

Page 3: ...125 CAUTION After installation make sure no fluid leaks from the valve pipe connections Improper piping may cause fluid leakage outside of the valve Do not put a load or weight on this product Doing s...

Page 4: ...ers 1 Total resistance Nominal 1 k Operation range 0 fully closed to 100 fully open Max applied voltage 5 V DC Note It cannot be connected with Model M904E Valve flange adapter kit 4 Valve size Major...

Page 5: ...on location Indoor use Note Salt air corrosive gas flammable gas and organic solvent must be avoided Outdoor use Note Salt air corrosive gas flammable gas and organic solvent must be avoided And use t...

Page 6: ...mperature of fluid Chilled hot water 0 175 C Note When using the stainless steel valve with chilled water of 0 C or lower please contact Azbil Corporation 175 C steam 0 175 C 200 C steam 0 200 C Flow...

Page 7: ...tion applied for the 4 20 mA DC input and 2 10 V DC input Output voltage range 2 V DC fully closed to 10 V DC fully open Maximum load resistance 10 k or more max output current 1 mA Valve position Ind...

Page 8: ...maintenance 2 For setting the auxiliary switch make sure to allow a clearance of 300 mm or more Figuar 1 Dimensions mm Table 1 Dimension table mm Valve size L L1 H H1 D C t h N DN15 108 50 213 75 95 7...

Page 9: ...For setting the auxiliary switch make sure to allow a clearance of 300 mm or more Figuar 2 Dimensions mm Table 2 Dimension table mm Valve size L L1 H H1 D C g t h N DN15 108 50 213 75 95 70 51 12 15 4...

Page 10: ...AB 6464 10 Parts Indication Actuator Yoke Valve body Pointer Terminal cover Top cover Knockout hole Top lid Top cover Joint Stem Gland packing Seat ring Plug Figuar 3 Parts Indication...

Page 11: ...ve install it on the pipe diverting sections for each piping group Do not install this product near a steam coil hot water coil etc High temperature radiant heat may cause failure of the actuator Avoi...

Page 12: ...he factory CAUTION After installation make sure no fluid leaks from the valve pipe connections Improper piping may cause fluid leakage outside of the valve Do not put a load or weight on this product...

Page 13: ...te A special sheet is inserted between the yoke and valve for heat insulation When you changed the mounting position be careful not to lose the sheet 4 Make sure that the groove on the tip of the valv...

Page 14: ...y of the power supply and 2 10 V DC feedback signal and then correctly wire the product Incorrect wiring may result in PCB print circuit board burnout z z How to maintain IP54 dust proof splash proof...

Page 15: ...terminals 4 to 7 Note Correctly connect the wires referring to Fig 9 to Fig 13 Terminals Connection Fig 14 to Fig 27 Wiring Examples and Advanced Wiring Examples 4 Mount the terminal cover and attach...

Page 16: ...troller V Voltage between 4 and 6 Figuar 10 z z Nominal 135 resistance input Model VY512_J 4 5 6 7 To controller 24 V AC power Open Open R B W T2 T1 1 3 2 Figuar 11 z z 4 20 mA DC input Model VY513_J...

Page 17: ...put Model VY513_ Model R35 Model R36 ACTIVAL 4 20 mA DC input Model VY513_ 4 5 6 7 T1 T2 1 2 1 3 2 Power transformer Model AT72 J1 100 200 V AC 1 The terminal 2 power terminal 5 4 20 mA DC input and t...

Page 18: ...ce life the minimum opening position cannot be maintained Avoid instrumentation that may cause secondary dam age in case of abnormality Figuar 18 Using relay interlock ACTIVAL Nominal 135 resistance i...

Page 19: ...duct will malfunction Input signals and power are shared Model R35TC0 Model R36TC0 ACTIVAL 4 20 mA DC input Model VY513_ Isolator 2 3 3 1 1 2 3 4 5 6 7 ACTIVAL 4 20 mA DC input Model VY513_ Isolator m...

Page 20: ...ed 2 Terminals 2 5 and 7 are internally connected 3 Refer to notes under Power transformer is shared Figuar 24 Power is shared Model WY5117 Model WY5117 ACTIVAL 2 10 V DC input Model VY514_ Isolator 2...

Page 21: ...ON Do not put a load or weight on this product Doing so may damage the product Before doing maintenance be sure to turn off the power to this product Failure to do so may result in electric shock or d...

Page 22: ...rminals Check the wirings Leakage is observed when the valve is fully closed Pointer position when the valve is fully closed Fully close the valve Abnormal sound or vibration is observed Check that le...

Page 23: ...AB 6464 23 This blank page was added for page layout purposes...

Page 24: ...al and Electronic Equipment Directive RoHSD EMCD EN 61000 6 2 EN 55011 Class A Group 1 RoHSD EN 50581 ACTIVAL is a trademark of Azbil Corporation Infilex is a trademark of Azbil Corporation Specificat...

Reviews: