Smoke machine and DMX troubleshooting

If you have a problem with your device, please consult the troubleshooting section for possible solutions. If, 
after consulting this section, the problem remains unresolved, please contact your dealer for more 
information and/or help. 

This troubleshooting section contains information on how to solve the most common smoke machine and 
DMX-related problems, but it does not and cannot cover every eventuality. It is possible that you won't find 
your problem, cause and solution in this section due to differences between various connecting devices. 

Problem

Possible cause

Solution

The device can not be 
turned on.

A fuse is blown

Check the fuse to rule out if it is blown or not. If it 
is blown, replace it with a new fuse of the same 
type and class.

Power cable not plugged in

Check if the power cable is properly connected to 
the device andplugged into an active power 
socket.

The device is not 
reacting to DMX signals

Incorrect DMX start address

Check if the device has been set to the correct 
DMX start address

DMX controller is on ‘Blackout’ Make sure the ‘Blackout’ function on the DMX 

controller is not activated

Make sure the polarity switch 
on the DMX controller is set 
correctly

Try to reverse the DMX polarity switch on the 
DMX controller.

The device is not reacting, 
there is no DMX signal 
indication

Make sure the XLR cables are connected 
properly and are not defective. Replace if 
necessary.

The smoke machine 
does not produce 
smoke

The device is still warming up

Check the status of the smoke machine by means
of the illuminated fluid tank. The machine is 
possibly still warming up.

Fluid tank is empty

If you can hear the pump working but the 
machine is not producing any smoke, then the 
fluid tank might be empty. Check the tank and 
add some fluid if necessary. 

Smoke machine is clogged

If the smoke output is very low and the smoke 
comes out in small, weak puffs, then the machine 
could be clogged. 

Thermal reset is activated

If there is a technical defect which disables the 
heating element from stopping once it reaches 
the correct temperature, (the digital thermostat 
should shut off), then the thermal reset will 
activate and switch off current flowing to the 
heating element. This can only be restored 
manually by pressing the reset button on the top 
of the machine. 
If you need to press the reset button several 
times to get the machine to work again and again,
something is probably wrong. If this is the case, 
turn the machine off completely and contact your 
dealer. 

The machine produces  Machine is cooling down

Shortly after the smoke machine is switched off, it

The information in this user manual is subject to change at any time without notice.

Version: 1.0

Date of creation and author's initials: 29-07-2017 RV

Revision date and author's initials: -

Summary of Contents for 9000-0033-5447

Page 1: ...03 DMX Fog Machine User manual The information in this user manual is subject to change at any time without notice Version 1 0 Date of creation and author s initials 29 07 2017 RV Revision date and au...

Page 2: ...it please remove the plug from the power socket and contact your dealer for assistance Box contents WSM Black smoke machine model 01 02 03 IEC C13 Schuko power cable 1 5 mm wired timer remote control...

Page 3: ...evice should not be fed with a signal higher than necessary The device should only be used indoors contact with water rain and moisture should always be avoided Do not place any objects containing liq...

Page 4: ...th the functions of this device before using it Should the device not be used in the manner described in this user manual damages or even injuries could occur Ayra cannot be held responsible for any i...

Page 5: ...y is incorrectly replaced Replace only with the same or equivalent type of battery Do not expose batteries to excessive heat such as sunshine fire and the like Do not leave batteries in an extremely h...

Page 6: ...perature settings of the smoke machine have been factory optimised and can not be adjusted by the user The smoke that comes out of this machine directly in front of the output nozzle is very hot Keep...

Page 7: ...table surface When suspended ensure that the smoke machine is mounted securely in a stable truss construction Do not lift or hold the machine during use The handles on this machine are designed to be...

Page 8: ...input through 3 pin XLR 9 DMX output through 3 pin XLR 10 IEC C14 power input with fuse holder 11 fluid level indicator The WSM Black 02 is shown above the WSM Black 01 and 03 models feature similar...

Page 9: ...og machine heater status LED ready to produce fog when illuminated yellow button timer function on or off red button continuous mode on or off green button manual production of fog based on the set fo...

Page 10: ...t damage may occur Positioning and installation The WSM Black smoke machine is designed to be used standing upright or suspended in a stable construction In order to prevent unauthorized use of this m...

Page 11: ...of current to the heating element If the temperature gets too high the bimetallic strip will bend instantly interrupting the current The interrupted current can only be repaired by manually pushing t...

Page 12: ...d outputs on the machine Using the wireless remote control The wireless remote control makes use of a radiographic FM signal and is therefore not direction sensitive It has a range of approximately 30...

Page 13: ...he pipework should now be free of fluid and the machine can be switched off and stored for an extended period of time When using the machine again after taking it out of storage it may take some time...

Page 14: ...k as described above When the machine is used again for the first time it will need some time to absorb the smoke fluid thoroughly and produce smoke normally PLEASE NOTE Never use drinking water from...

Page 15: ...reacting there is no DMX signal indication Make sure the XLR cables are connected properly and are not defective Replace if necessary The smoke machine does not produce smoke The device is still warm...

Page 16: ...ment or thermal component is not functioning If the heating element or other internal component is not functioning properly this can cause the output nozzle to spray fluid If you are unsure whether th...

Page 17: ...cator and protective cover mounting bracket hardware for mounting bracket battery type for remote control battery type A23 12V L1028 LR23A already installed Specifications per model Feature WSM 01 Bla...