background image

You can use the timer function to set smoke intervals and duration, or regulate a smooth output that ranges 
from 0 to 100%. The remote has buttons for triggering the machine manually or producing a steady output 
level. 

The LED indicators on the remote show you which function is active at any given time as well as the status of
the smoke machine.

Installing the machine

All WSM Black smoke machines come with a mounting bracket for installation on a light stand or truss.

To avoid the risk of injury due to hot spatters of smoke fluid, do not mount the smoke machine directly above 
the location of your audience. There should be a horizontal distance of at least 2 metres between the 
machine's output nozzle and your closest audience member.  If this is not possible, try rotating the machine 
or mount it at a lower level. 

Do not mount this machine at an angle greater than 15 degrees. 

Storage and transportation

If you do not intend to use the smoke machine within 2 to 4 weeks after using it last, it is recommended to 
empty the fluid tank completely. This prevents any fluid or residue from getting into the internal components 
and clogging the machine.

In order to empty the pipework of all fluid, the smoke machine needs to be switched on and ready for use. 
Open the lid of the machine and remove the siphon. Place it in an empty plastic cup for instance, so it 
doesn't fall on the floor and get dirty. 

Start the machine by pressing the button manually or using one of the remote controls until the amount of 
smoke has reduced significantly, or until the pump starts to make noise. When this happens, stop the 
machine immediately. The pipework should now be free of fluid and the machine can be switched off and 
stored for an extended period of time.

When using the machine again after taking it out of storage, it may take some time before the fluid is passed 
throughout the system. During this process, the pump will make some noise at first, but this will eventually 
decrease and smoke will come out. 

Do not run the machine too long without fluid, as this can cause permanent damage to the pump. Cleaning 
out the machine ensures the internal components are free of fluid residue and prevents clogging.

Switching off and cooling down the smoke machine

When the machine is no longer being used (and optionally drained), then it can be switched off. Bear in mind
that the machine can not be transported directly after it has been switched off.

The machine requires at least 20 minutes to cool down after use. The heating element needs to time to cool 
down to a temperature that makes it less vulnerable to damage caused by shocks and bumps which may 
occur during transport. 

Transporting the machine directly after it has been switched off could damage the heating element and result
in a machine that no longer warms up when turned on.

It is therefore strongly advised to give the machine time to cool down after use before transporting it. 

During the cooling-down period, the machine may produce small plumes of smoke.

Less or no smoke production - what to do

If the machine starts to produce less smoke or none at all, then it might be clogged. To solve this problem, 
the pump needs to be in working order.

If the pipework is clogged, try clearing it by making a special cleaning fluid.

The information in this user manual is subject to change at any time without notice.

Version: 1.0

Date of creation and author's initials: 29-07-2017 RV

Revision date and author's initials: -

Summary of Contents for 9000-0033-5447

Page 1: ...03 DMX Fog Machine User manual The information in this user manual is subject to change at any time without notice Version 1 0 Date of creation and author s initials 29 07 2017 RV Revision date and au...

Page 2: ...it please remove the plug from the power socket and contact your dealer for assistance Box contents WSM Black smoke machine model 01 02 03 IEC C13 Schuko power cable 1 5 mm wired timer remote control...

Page 3: ...evice should not be fed with a signal higher than necessary The device should only be used indoors contact with water rain and moisture should always be avoided Do not place any objects containing liq...

Page 4: ...th the functions of this device before using it Should the device not be used in the manner described in this user manual damages or even injuries could occur Ayra cannot be held responsible for any i...

Page 5: ...y is incorrectly replaced Replace only with the same or equivalent type of battery Do not expose batteries to excessive heat such as sunshine fire and the like Do not leave batteries in an extremely h...

Page 6: ...perature settings of the smoke machine have been factory optimised and can not be adjusted by the user The smoke that comes out of this machine directly in front of the output nozzle is very hot Keep...

Page 7: ...table surface When suspended ensure that the smoke machine is mounted securely in a stable truss construction Do not lift or hold the machine during use The handles on this machine are designed to be...

Page 8: ...input through 3 pin XLR 9 DMX output through 3 pin XLR 10 IEC C14 power input with fuse holder 11 fluid level indicator The WSM Black 02 is shown above the WSM Black 01 and 03 models feature similar...

Page 9: ...og machine heater status LED ready to produce fog when illuminated yellow button timer function on or off red button continuous mode on or off green button manual production of fog based on the set fo...

Page 10: ...t damage may occur Positioning and installation The WSM Black smoke machine is designed to be used standing upright or suspended in a stable construction In order to prevent unauthorized use of this m...

Page 11: ...of current to the heating element If the temperature gets too high the bimetallic strip will bend instantly interrupting the current The interrupted current can only be repaired by manually pushing t...

Page 12: ...d outputs on the machine Using the wireless remote control The wireless remote control makes use of a radiographic FM signal and is therefore not direction sensitive It has a range of approximately 30...

Page 13: ...he pipework should now be free of fluid and the machine can be switched off and stored for an extended period of time When using the machine again after taking it out of storage it may take some time...

Page 14: ...k as described above When the machine is used again for the first time it will need some time to absorb the smoke fluid thoroughly and produce smoke normally PLEASE NOTE Never use drinking water from...

Page 15: ...reacting there is no DMX signal indication Make sure the XLR cables are connected properly and are not defective Replace if necessary The smoke machine does not produce smoke The device is still warm...

Page 16: ...ment or thermal component is not functioning If the heating element or other internal component is not functioning properly this can cause the output nozzle to spray fluid If you are unsure whether th...

Page 17: ...cator and protective cover mounting bracket hardware for mounting bracket battery type for remote control battery type A23 12V L1028 LR23A already installed Specifications per model Feature WSM 01 Bla...