Guidelines for fog machines

Fluid guidelines:

- Only use water-based fog liquids!
- Ayra recommends the use of Ayra fog machine fluid only. Other types of fog liquid may cause permanent 
damage or bad performance. When the wrong type of fog liquid is used, the machine might spray hot liquid. 
- It is possible to keep fog machine fluid in the tank during transport. Pay close attention to possible tipping. 
When transporting this device with fluid still in the tank, the maximum level should not exceed 50%!
- When transporting this device with parcel delivery companies (or any other way of transport where the 
device could be positioned upside-down), the fluid tank needs to be fully drained.

Temperature guidelines:

- The fog machine requires a heat-up time. It is not directly ready for use when switched on.
- The temperature of the heating element is set in the factory. Do not attempt to change the set temperature 
of the device.
- The fog coming out of the fog machine is very hot and moist at short distance. Keep animals, children, 
flammable objects and electronic devices away from the fog machine and its output.
- After use, turn off the machine, unplug the power cable from its socket and let the machine cool down for at 
least 20 minutes. Do not transport the machine while it is still hot! Small puffs of fog may be produced during 
cool-down time. 

Ventilation and health guidelines:

- Always make sure that there is sufficient ventilation in the room. Fresh air needs to be able to enter the 
room and vaporized fog needs to be able to be drained from the room.
- Use caution with the amount of fog used. Only small amounts of fog are required to accentuate professional
lighting and make the beams visible. Do not keep producing fog when the visibility drops below 2 meters.
- The use of fog is not hazardous for people or animals, if used with caution and proper ventilation. Do not 
use more fog than needed to achieve the desired effect.

Exterior guidelines:

- Do not cover the nozzle of the fog machineor place a tube over the nozzle.
- When using the fog machine in a standing or hanging position, do not adjust the vertical angle by more than
15% up or down.
- When used in a hanging position, the device always needs to be secured by using a safety cable. Attach 
the safety cable to the provided safety eye with the carabiner hook. A safety cable is not included in the 
delivery and can be purchased separately.
- The device must be installed on a flat surface or hang from a solid construction  using the included bracket. 

The information and illustrations shown in this user manual are subject to change without  notice.

User manual version: 1.0

Creation date + author initials: 03-11-2015 RV Revision date + author initials: -

WARNING!

This machine has a built-in heating element. The housing of this device may become very hot 
during use. Do not touch the housing of the device during use and do not place your hand in 
front of the fog machine output nozzle!

WARNING!

Large amounts of fog in a badly ventilated room may cause headaches, lightheadedness, 
dizzyness and possible other health-related issues. If any of these symptoms occur, stop 
producing fog immediately and open a door or window to let fresh air into the room.

Summary of Contents for 9000-0021-6270

Page 1: ...ith wired remote control User manual The information and illustrations shown in this user manual are subject to change without notice User manual version 1 0 Creation date author initials 03 11 2015 RV Revision date author initials ...

Page 2: ...e filled with proper fog fluid in order to create the desired fog effect Fluid from the tank is pumped into the heating system which then expands into a fog like substance The expansion causes the pressure to build until clouds of fog are expelled from the nozzle positioned at the front of the machine The WSM Junior uses water based fluids Ayra recommends the use of Ayra fluids which are available...

Page 3: ...cables Handle the power cord and all mains connectors with caution Never remove any warning or informative labels from the unit Never leave cables lying around Do not open the device and do not modify any hardware or software Do not insert objects into air vents of this device Do not connect this device to a dimmer pack Do not switch the system on and off frequently as this will reduce the lifespa...

Page 4: ... device to a power outlet with the wrong type of voltage or using the product with a wrong type of power supply may cause permanent damage to the device Avoid shocks and collisions during use and transport Do not transport the device while in use Avoid brute force during the installation and operation of this device Familiarise yourself with the functions of the device before use Do not allow oper...

Page 5: ...he requirements stated in this directive apply to all manufacturers and producers of electronic equipment in the EU Do not dispose of this product together with regular household rubbish Contact your local government representative for more information about proper disposal and recycling of electronic products in your region By recycling this product properly after use we can work together to enjo...

Page 6: ...d fog needs to be able to be drained from the room Use caution with the amount of fog used Only small amounts of fog are required to accentuate professional lighting and make the beams visible Do not keep producing fog when the visibility drops below 2 meters The use of fog is not hazardous for people or animals if used with caution and proper ventilation Do not use more fog than needed to achieve...

Page 7: ...he device in a hanging position always mount a G clamp or half coupler to the bracket or use bolts to install the bracket directly to a ceiling or beam The information and illustrations shown in this user manual are subject to change without notice User manual version 1 0 Creation date author initials 03 11 2015 RV Revision date author initials ...

Page 8: ...onnect it from the power supply and store it in a dust free environment Always check the unit for possible damage before use If you suspect that something is wrong with the unit do not connect it to a power source When you suspect that your unit is broken or damaged contact your local dealer or a certified technician to inspect the unit The information and illustrations shown in this user manual a...

Page 9: ...On off switch 8 Power input 9 Fluid level view 10 Fluid tank cap 11 Remote control button 12 LED status indicators The information and illustrations shown in this user manual are subject to change without notice User manual version 1 0 Creation date author initials 03 11 2015 RV Revision date author initials 1 2 3 4 5 6 7 12 8 9 10 11 ...

Page 10: ...skilled technician for the best installation advice for permanent and mobile setups Installing the fixture in a hanging position The WSM Junior is equipped with an installation bracket which makes it possible to install the device on a ceiling or beam Mounting hardware is not included but should be available at your local hardware store Please ensure that the right mounting hardware is selected fo...

Page 11: ...l turned on but about to be shut down twist the cap off the fluid tank and remove the hose from the tank The fluid tank can be drained for example in the original fog fluid container Now spray fog until the output of the machine drops significantly This way remaining fluid which is trapped inside the heating system will be removed If noise from the pump increases and the fog output becomes low sto...

Page 12: ...active Check your power source wall outlet or power strip and make sure there is an accurate voltage provided for the machine Fog machine heater is not active No power Check the power indicator light on the switch If not lit the machine is not turned on Heater broken Contact your local dealer for help and support No fog produced Fog liquid tank empty Check the fog machine fluid tank and fill it up...

Page 13: ...g time 4 to 5 minutes tank capacity 0 3 liter output power 300cft 8 5 m per minute Technical details Power supply 230V 50 Hz Fuse F5AL250V Power consumption 400W max ta 0 40º Celsius Fluid tank capacity 0 3l Exterior surface temp 56 4º Celsius Power factor 0 99 The information and illustrations shown in this user manual are subject to change without notice User manual version 1 0 Creation date aut...

Reviews: