Axpert MLV-5KW-48V User Manual Download Page 33

31 

 

Table 3: Charging Mode Specifications

 

Utility Charging Mode

 

INVERTER MODEL 

5KVA 

Charging Current (UPS) 

@ Nominal Input Voltage

 

2A/10A/20A/30A/40A/50A/60A 

Bulk 
Charging 
Voltage 

Flooded Battery 

58.4Vdc 

AGM / Gel 
Battery 

56.4Vdc 

Floating Charging Voltage 

54Vdc 

Overcharge Protection 

60Vdc 

Charging Algorithm 

3-Step 

Charging Curve 

Solar Charging Mode(Per number of MPPT) 

INVERTER MODEL 

5KVA 

Rated Power 

4000*2 W 

Max. efficiency 

96% 

Max. PV Array Open Voltage 

145Vdc 

PV Array MPPT Voltage 
Range 

60~115Vdc 

Min. battery voltage for PV 
charge 

34Vdc 

Standby Power Consumption 

<23W 

Battery Voltage Accuracy 

+/-0.3% 

PV Voltage Accuracy 

+/-2V 

Charging Algorithm 

3-Step 

Joint Utility and Solar Charging 
INVERTER MODEL 

5KVA 

Max. Charging Current   

220A

 

Default Charging Current 

60Amp 

 

Summary of Contents for MLV-5KW-48V

Page 1: ...LV 5KVA 48V INVERTER CHARGER Version 1 0 User Manual...

Page 2: ...10 Communication Connection 12 Dry Contact Signal 12 OPERATION 13 Power ON OFF 13 Operation and Display Panel 13 LCD Display Icons 14 LCD Setting 16 Display Setting 23 Operating Mode Description 25 Fa...

Page 3: ...g Turning off the unit will not reduce this risk 5 CAUTION Only qualified personnel can install this device with battery 6 NEVER charge a frozen battery 7 For optimum operation of this inverter charge...

Page 4: ...suit different applications via LCD setting Configurable priority of AC Solar Charger via LCD setting Compatible to mains voltage or generator power Automatic restart while AC is recovering Overload...

Page 5: ...cation port 5 RS232 communication port 6 PV input 7 Parallel communication port only for parallel model 8 Current sharing port only for parallel model 9 Parallel ID 10 AC output 11 Circuit breaker 12...

Page 6: ...l Do not mount the inverter on any flammable construction materials Mount this inverter on a solid surface Install this inverter at eye level in order to read the LCD display at all times The ambient...

Page 7: ...5...

Page 8: ...size of terminal recommended below Recommended battery cables and size of terminal Model Typical Amperage Battery Capacity Wire Size Ring Terminal Torque Value Cable mm2 Dimensions D mm L mm 5KW 220A...

Page 9: ...rce This will ensure the inverter can be securely disconnected during maintenance and fully protected from over current of AC input The recommended spec of AC breaker is 40A for 5KVA CAUTION There are...

Page 10: ...120V 120V L2 240V 240V When the phase angle between L1 and L2 is 180 Please follow below steps to implement AC input output connection 1 Before making AC input output connection be sure to open DC pro...

Page 11: ...olarity If L and N wires are connected reversely it may cause utility short circuited when these inverters are worked in parallel operation CAUTION Appliances such as air conditioner are required at l...

Page 12: ...n circuit Voltage Voc of PV modules should be higher than the minimum voltage of the battery Please follow the steps below to implement PV module connection 1 Remove insulation sleeve 10 mm from posit...

Page 13: ...11...

Page 14: ...Dry contact port NC C NO C Power Off Unit is off and no output is powered Close Open Power On Output is powered from Utility Close Open Output is powered from Battery or Solar Program 01 set as Utili...

Page 15: ...ing the operating status and input output power information LED Indicator LED Indicator Messages Green Solid On Output is powered by utility in Line mode Flashing Output is powered by battery or PV in...

Page 16: ...ing code Fault lighting with fault code Output Information Indicate output voltage output frequency load percent load in VA load in Watt and discharging current Battery Information Indicates battery l...

Page 17: ...817V cell 1 817V cell 1 9V cell 1 9 1 983V cell 1 983 Load 20 1 867V cell 1 867V cell 1 95V cell 1 95 2 033V cell 2 033 Load Information Indicates overload Indicates the load level by 0 24 25 50 50 74...

Page 18: ...s only when any one condition stated below happens Solar energy is not available Battery voltage drops to either low DC warning voltage or the setting point in program 12 Utility first default Utility...

Page 19: ...ing current 40A 50A 60A 70A 80A 90A 100A 110A 120A 130A only for 5KVA with MPPT models 140A 150A 160A 170A 180A 190A 200A 210A 220A 03 AC input voltage range Appliances default If selected acceptable...

Page 20: ...t enable 07 Automatically restart when over temperature occurs Restart disable default Restart enable 08 Output voltage 110V 120V default 09 Output frequency 50Hz default 60Hz 11 Maximum utility charg...

Page 21: ...t Solar energy will charge battery as first priority Utility will charge battery only when solar energy is not available Utility first Utility will charge battery as first priority Solar energy will c...

Page 22: ...ault Alarm off 23 Overload bypass When enabled the unit will transfer to line mode if overload occurs in battery mode Bypass disable default Bypass enable 25 Record Fault code Record enable Record dis...

Page 23: ...g according to rule of solar first setting For example two units are connected in parallel and set SOL in output source priority If one of the two units has connected to PV modules and PV input is nor...

Page 24: ...elected inverter will judge this charging time automatically 5 min The setting range is from 5 min to 900 min Increment of each click is 5 min 900 min If USE is selected in program 05 this program can...

Page 25: ...e Display Setting The LCD display information will be switched in turns by pressing UP or DOWN key The selectable information is switched as below orde Selectable information LCD display AC Input 1 vo...

Page 26: ...200W MPPT Input 2 Charging current MPPT Input 2 Charging power PV2 voltage 60V PV2 Power 200W Load 1 Watt Load 1 percentage Load 1 Watt 200W Load 1 percent 60 Load 2 Watt Load 2 percentage Load 2 Wat...

Page 27: ...rging current 25A Battery voltage 56 0V Battery voltage DC discharging current Battery voltage 53 0V discharging current 1A Main CPU version checking Main CPU version 00014 04 Secondary CPU version ch...

Page 28: ...charging Fault mode Note Fault mode Errors are caused by internal circuit errors or external reasons such as over temperature output short circuited and so on PV energy can charge the batteries Charg...

Page 29: ...tected by internal converter components 06 Output voltage is too high 07 Overload time out 08 Bus voltage is too high 09 Bus soft start failed 11 Main relay failed 51 Over current or surge 52 Bus volt...

Page 30: ...nd 03 Battery is over charged Beep once every second 04 Low battery Beep once every second 07 Overload Beep once every 0 5 second 10 Output power derating Beep twice every 3 seconds 12 Solar charger s...

Page 31: ...Nominal Input Frequency 50Hz 60Hz Auto detection Low Loss Frequency 40 1Hz Low Loss Return Frequency 42 1Hz High Loss Frequency 65 1Hz High Loss Return Frequency 63 1Hz Output Short Circuit Protectio...

Page 32: ...s 150 load 10s 110 150 load Surge Capacity 2 rated power for 5 seconds Nominal DC Input Voltage 48Vdc Cold Start Voltage 46 0Vdc Low DC Warning Voltage load 20 44 0Vdc 20 load 50 42 8Vdc load 50 40 4V...

Page 33: ...60Vdc Charging Algorithm 3 Step Charging Curve Solar Charging Mode Per number of MPPT INVERTER MODEL 5KVA Rated Power 4000 2 W Max efficiency 96 Max PV Array Open Voltage 145Vdc PV Array MPPT Voltage...

Page 34: ...2 Table 4 General Specifications INVERTER MODEL 5KVA Safety Certification CE Operating Temperature Range 0 C to 55 C Storage temperature 15 C 60 C Dimension D W H mm 130 x 622 6 x 610 Net Weight kg 30...

Page 35: ...play and LEDs are flashing Battery is disconnected Check if battery wires are connected well Buzzer beeps continuously and red LED is on Fault code 07 Overload error The inverter is overload by 110 an...

Page 36: ...0Ah min 5KVA 500 1226 2576 1000 536 1226 1500 316 804 2000 222 542 2500 180 430 3000 152 364 3500 130 282 4000 100 224 4500 88 200 5000 80 180 Note Backup time depends on the quality of the battery ag...

Page 37: ...N wires must be connected together 2 Package Contents In parallel kit you will find the following items in the package Parallel communication cable Current sharing cable 3 Mounting the Unit When inst...

Page 38: ...recommended mounted location of the breakers is shown in the parallel diagrams in section 5 1 and 5 2 Recommended specification of battery breaker for each inverter Model 1 unit 5KVA 125A 80VDC If yo...

Page 39: ...37 4 1 Parallel Operation in Single phase Two inverters in parallel 0 Power Connection Load L N L N L1L2 L1L2 Communication Connection Three inverters in parallel 0 Power Connection...

Page 40: ...38 Communication Connection...

Page 41: ...39 4 2 Support 2 phase equipment Two inverters in parallel 120 Power Connection Load L1 L2 L1 L2 N Communication Connection Two inverters in parallel 180 Power Connection...

Page 42: ...40 Load L1 L2 N L1 L2 N Communication Connection Three inverters in parallel 120 Power Connection...

Page 43: ...41 Load L1 L2 L1 L2 N Communication Connection Three inverters in parallel 180 Power Connection Load L1 L2 N L1 L2 N Communication Connection...

Page 44: ...nect the current sharing cables between the inverters in different phases Otherwise it may damage the inverters NOTE For parallel model operation please refer to LCD program 28 5 PV Connection Please...

Page 45: ...nnected to L3 phase Be sure to connect shared current cables to units in the same phase Do NOT connect shared current cables between units in different phases Phase 1 of 3 Phase output Phase 2 of 3 Ph...

Page 46: ...nnected to PV modules For example two units are connected in parallel and set SOL in output source priority When ALL is selected in program 30 it s necessary to have all inverters connected to PV modu...

Page 47: ...le phase Step 1 Check the following requirements before installation Correct wire connection Ensure all breakers in Line wires at load side are open and each Neutral wires of each unit is connected to...

Page 48: ...f switch when setting LCD program Otherwise the setting cannot be programmed Step 3 Turn on all units sequentially LCD display in L1 phase unit LCD display in L2 phase unit LCD display in L3 phase uni...

Page 49: ...ct your installer 81 Host data loss 82 Synchronization data loss 83 The battery voltage of each inverter is not the same 1 Make sure all inverters share the same groups of batteries together 2 Remove...

Reviews: