15
V220308
3.4.2 Handling and placement of the base
The base is light, a single person can handle it.
3.4.3 Selection of installation sites
A. The AXIstorage Li SV1 system
’
s working temperature range is 0
℃
~
50
℃
; Optimum temperature:
18
℃
~
28
℃
. Do not place the battery system in direct sunlight. It is suggested to build sunshade
equipment. In cold area a heating system is required.
B. The AXIstorage Li SV1 system must not be immersed in water. The battery base cannot be
placed in rain or other water sources.
As a suggestion, the base’s height
shall be >300mm above
the ground.
C. The basement must bear the weight of whole battery system (130~300kg).
D. The AXIstorage Li SV1 system must be installed on fixed ground.
3.4.4 Packing list
BMS SV1 Battery Controller
Item
Description
Set
1
BMS SV1 Battery Controller
1
2
AXIstorage Li SV1 basement (600*380*40, mm)
1
3
EPE foam
3
4
3.5m black external communication cable (RJ45
–
M19)
2
5
3.5m DC+ red external power cable (10AWG)
1
6
3.5m DC- black external power cable (10AWG)
1
7
1m yellow-green grounding cable (10AWG)
1