AXIS T99A12 Positioning Unit 24 V AC/DC
RS485/RS422 connector
Two 2-pin terminal blocks for RS485/RS422 serial interface used to control auxiliary equipment
such as pan-tilt devices.
The serial port can be configured to support:
•
Two-wire RS485 half duplex
•
Four-wire RS485 full duplex
•
Two-wire RS422 simplex
•
Four-wire RS422 full duplex point to point communication
Function
Pin
Notes
RS485/RS422 RX/TX A 1
RS485/RS422 RX/TX B 2
(RX) For full duplex RS485/RS422
(RX/TX) For half duplex RS485
RS485/RS422 TX A
3
RS485/RS422 TX B
4
(TX) For full duplex RS485/RS422
Cables
Cable thickness
The cable diameter, when using cable gaskets provided with the product, should be in the range of
5 to 11 mm (0.2 to 0.4 in).
NO
NO
NOTICE
TICE
TICE
• Use cables that keep within the specified cable area
• Select cables in compliance with your local regulations
• Make sure all cable holes are properly sealed
• Use cable gaskets or cable glands that match both the cable hole and the cable area
For information about accessories, such as cable gaskets and cable glands that allow for other
cable areas, see
www.axis.com
28
Summary of Contents for T99A12
Page 1: ...AXIS T99A12 Positioning Unit 24 V AC DC Installation Guide ...
Page 2: ......
Page 3: ...EN FR DE IT ES JA ZH English Français Deutsch Italiano Español 日本語 中文 简体中文 ...
Page 6: ......
Page 30: ...30 ...
Page 54: ...54 ...
Page 78: ...78 ...
Page 102: ...102 ...
Page 126: ...126 ...
Page 150: ...150 ...
Page 165: ...AXIS T99A12 Positioning Unit 24 V AC DC 4 将底盖向后倾斜至其终端位置 然后拧紧定位单元前面的两颗螺丝 T20 扭矩 3 0 Nm 165 ZH ...