10. Place the transparent base unit cover on the base unit and fit the cable gaskets inside
the holes.
1
I/O connector
2
Power connector
3
O-ring
NO
NO
NOTICE
TICE
TICE
To not accidentally disconnect the unit from power if the cable is pulled, let the protective
grounding wire be about 10 mm (0.4 in) longer than the other two wires (in the power
cable).
Note
To make the installation as easy as possible, we recommend you to strip approximately 90
mm (3.5 in) of the power cable jacket and 70 mm (2.8 in) of the I/O cable jacket.
11. Install the power and I/O connectors.
12. Adjust the network, I/O and power cables so that the distance from the cable gasket to
the end of the connector is 240 mm (10 in), 170 mm (7 in), and 160 mm (7 in) respectively.
NO
NO
NOTICE
TICE
TICE
Make sure that the O-ring is fitted correctly around the transparent base unit cover.