AXIS Q6045 PTZ Dome Network Camera
System Options
2. Click
Network Share
.
3. Enter the IP address, DNS or Bonjour name to the host server in the
Host
field.
4. Enter the name of the share in the
Share
field. Sub folders cannot be used.
5. If required, select
The share requires login
and enter the user name and password.
6. Click
Connect
.
To clear all recordings and data from the Axis product’s folder on the designated share, click
Clear
under
Storage Tools
.
To avoid filling the share, it is recommended to remove recordings continuously. Under
Recording Settings
, select
Remove recordings
older than
and select the number of days or weeks.
To stop writing to the share and protect recordings from being removed, select
Lock
under
Recording Settings
.
Ports & Devices
I/O Ports
The Axis product provides four configurable input and output ports for connection of external devices. A multi-connector cable
(available from Axis) is required when connecting external devices, see
Multi-Connector Cable (sold separately), on page 58
.
The I/O ports are configured under
System Options > Ports & Devices > I/O Ports
. Select the port direction (
Input
or
Output
). The
ports can be given descriptive names and their
Normal states
can be configured as
Open circuit
or
Grounded circuit
.
Port Status
The list on the
System Options > Ports & Devices > Port Status
page shows the status of the product’s input and output ports.
Note
A multi-connector cable (available from Axis) is required when connecting I/O devices to the Axis product. See
Multi-Connector Cable (sold separately), on page 58
.
Maintenance
The Axis product provides several maintenance functions. These are available under
System Options > Maintenance
.
Click
Restart
to perform a correct restart if the Axis product is not behaving as expected. This will not affect any of the current
settings.
Click
Restore
to reset most settings to the factory default values. The following settings are not affected:
•
the boot protocol (DHCP or static)
•
the static IP address
•
the default router
•
the subnet mask
•
the system time
•
the IEEE 802.1X settings
•
uploaded applications are kept but must be restarted
Click
Default
to reset all settings, including the IP address, to the factory default values. This button should be used with caution. The
Axis product can also be reset to factory default using the control button, see
Reset to Factory Default Settings, on page 57
.
To test the product’s PTZ mechanics, click
Test
under
PTZ Status
.
55