7
-
CABLE CONNECTION
Proceed as follows to connect the power supply wire to the terminal block:
( A1 ) Loosen the tops of the cable gland and remove the bottom panel on the back of the appliance by
removing the screws.
( A2 ) Feed the new cable through the cable gland. Connect the cable voltage to the terminal strips
following the connection diagram on the label on the back of the appliance. Only connect what is indicated
inserting the copper bridge and the electricity cable together under the screws, in the tightening direction,
so the cable and the bridge are tightly fixed by tightening the screw. The type of cable to be used (HO7RN-
F) is indicated on the label for each connection and the wire size is in mm².
( A4 ) Close the bottom panel of the back of the appliance with the screws and secure the cable by
tightening the cable gland nut.
Incorrect connection could lead to overheating of the terminal board which could lead to blowout and
electric shock.
Check that all the connections
are tight before connecting the
oven to the mains.
PE = GND = Yellow/Green:
“EARTH” protection
conductor.
N = Blue: neutral conductor.
L1, L2, L3 = Brown, Grey,
Black: live conductors
Check there is no static
discharge between live and
earth. Check the limit switch
continuity between the
external casing and the earth
wire of the mains. It is
advised to use a multi tester
to
AXIS MODELS
Connection references
AX-513
ETI00021
AX-513H
ETI00022
AX-513RHD
ETI00022
AX-514
ETI00022
AX-514H
ETI00022
AX-514RHD
AX-824H
ETI00019
AX-824RHD
ETI00019
ETI00022