2. Function 

 

Button 

Operation Performed 

HOLD 

Press 

HOLD 

to enter the Hold mode any mode,

appears and the Meter beeps. 

Press 

HOLD 

again to exit the Hold mode to return to measurement mode, the Meter 

beeps and,

disappears. 

 

Press the backlight button when needed. Auto shut-down backlight after lighting 
20secs.Press the button again, turn the backlight off manually  

∑ 

At Active power (main display) + Phase angle (secondary display) mode, press 

 once 

button to sum up the current phase of 3 phase measurement result. Then carry out 
second phase power measurement. 

Press 

∑ 

and hold for over 1 second to sum up the phase power measurement result 

which had been selected. 

if you didn`t select any phase of 3 phase, 

∑ 

is invaild. 

SAVE 

Press once to store single reading, and the Meter beeps.The index number shown on 
the left secondary display keep on increasing. The maximum number of data store is 
99, when it achieves 99, the Meter shows 

.  

SEL 

Press 

SEL 

button to step through first phase, second phase, third phase and sum of 

watts. 

Press

 SEL

 and hold for over 2 second to enter 3P3W mode. 

MAXMIN 

Press to start recording of maxinmum it valid at voltage, current, active power and 
apparent power ranges only. 

CLEAR 

At active energy range, press 

CLEAR

  and hold for over 1 second to reset time the 

zero, then restart the timing. 

At all other ranges, press 

CLEAR

  and hold for over 1 second to clear stored 

Summary of Contents for AX-3550

Page 1: ...Digital clamp meter AX 3550 Instruction Manual...

Page 2: ...er 4 When measurement has been completed disconnect the connection between the test leads and the circuit under test remove the esting leads away from the input terminals of the Meter and turn the Met...

Page 3: ...um up the phase power measurement result which had been selected if you didn t select any phase of 3 phase is invaild SAVE Press once to store single reading and the Meter beeps The index number shown...

Page 4: ...ry switch deasil to make the position away from the OFF position Hearing a beep sound indicates the meter is turned on The LCD displays all symbols firstly and then return to the normal mode If the sy...

Page 5: ...of phase angle KVAr The unit of reactive power W Watt Sum of Watt The battery is low Warning To avoid false readings which could lead to possible electric shock or personal injury replace the battery...

Page 6: ...uency symbol MEM Indicator for data store FUL Indicator for data stored is full Data hold is active 4 Specifications AC Voltage True RMS Range Resolution Accuracy Allowable Maximum overload protection...

Page 7: ...racy Allowable Maximum overload protection current Frequency Range 40A 0 1A 2 5 1000A RMS 50Hz 60Hz 100A 400A 1000A 1A Active Power W V x A x COS Current Voltage Voltages Range 100V 400V 750V Current...

Page 8: ...Power VA V x A Current Voltage Voltages Range 100V 400V 750V Current Range 40A 4 00KVA 16 00KVA 30 00KVA 100A 10 00KVA 40 00KVA 75 00KVA 400A 40 00KVA 160 0KVA 300 0KVA 1000A 100 0KVA 400 0KVA 750 0K...

Page 9: ...1000KVAr 0 01KVAr 100kW 0 1KVAr Power Factor PF W VA Range Accuracy Resolution Measuring Condition 0 3 1 capacitive or inductive 0 022 0 001 The minimum measuring current 10A The minimum measuring vol...

Page 10: ...Measuring current less than 10A OR Measuring voltage less than 45V Remarks Allowable maximum overload protection voltage 750V RMS Allowable maximum overload protection current 1000A RMS Basic Functio...

Page 11: ...00Hz Active Energy 0 001 9999 kWh 3 2 digits Temperature 50O C 1300O C 58O F 2372O F Special Functions Auto Ranging Single phase 2 wire Balance 3 phase 3 wire 3 phase 4 wire True RMS AC Voltage or Cur...

Page 12: ...y as soon as the battery indicator appears With a low battery the Meter might produce false readings that can lead to electric shock and personal injury 2 When opening the battery door must make sure...

Reviews: