readings.  

MR 

Press once to enter Memory Record mode, 

 appears and the Meter beeps. 

▼/▼ 

If the Meter steps through sum of power press 

▼/▼ 

button to switch display of active 

power (main display) , sum of reactive power (secondary display) , sum of power 
factor (main display) and sum of apparent power. 

In the MR mode, press 

▼/▼ 

to select recoded data. 

USB 

Measurement data will be sent to the PC 

2.1. Additional inforamtion 

 

1.

 

Turn the rotary switch deasil to make the position away from the OFF position. Hearing a 
beep sound indicates the meter is turned on. The LCD displays all symbols firstly and then 
return to the normal mode. If the symbol

 is displayed, please changed the battery. 

2.

 

After auto-shut-off, there are some parts of the circuit of the meter which is still work. If 
no measurement needed in a longer time, you’d better turn the rotary switch back to the 
OFF position. 

3.

 

Press the backlight button when needed. Auto shut-down backlight after lighting 
18secs.Press the button again, turn the backlight off manually 

3. Display symbols 

 

Figure 1 

 

Summary of Contents for AX-3550

Page 1: ...Digital clamp meter AX 3550 Instruction Manual...

Page 2: ...er 4 When measurement has been completed disconnect the connection between the test leads and the circuit under test remove the esting leads away from the input terminals of the Meter and turn the Met...

Page 3: ...um up the phase power measurement result which had been selected if you didn t select any phase of 3 phase is invaild SAVE Press once to store single reading and the Meter beeps The index number shown...

Page 4: ...ry switch deasil to make the position away from the OFF position Hearing a beep sound indicates the meter is turned on The LCD displays all symbols firstly and then return to the normal mode If the sy...

Page 5: ...of phase angle KVAr The unit of reactive power W Watt Sum of Watt The battery is low Warning To avoid false readings which could lead to possible electric shock or personal injury replace the battery...

Page 6: ...uency symbol MEM Indicator for data store FUL Indicator for data stored is full Data hold is active 4 Specifications AC Voltage True RMS Range Resolution Accuracy Allowable Maximum overload protection...

Page 7: ...racy Allowable Maximum overload protection current Frequency Range 40A 0 1A 2 5 1000A RMS 50Hz 60Hz 100A 400A 1000A 1A Active Power W V x A x COS Current Voltage Voltages Range 100V 400V 750V Current...

Page 8: ...Power VA V x A Current Voltage Voltages Range 100V 400V 750V Current Range 40A 4 00KVA 16 00KVA 30 00KVA 100A 10 00KVA 40 00KVA 75 00KVA 400A 40 00KVA 160 0KVA 300 0KVA 1000A 100 0KVA 400 0KVA 750 0K...

Page 9: ...1000KVAr 0 01KVAr 100kW 0 1KVAr Power Factor PF W VA Range Accuracy Resolution Measuring Condition 0 3 1 capacitive or inductive 0 022 0 001 The minimum measuring current 10A The minimum measuring vol...

Page 10: ...Measuring current less than 10A OR Measuring voltage less than 45V Remarks Allowable maximum overload protection voltage 750V RMS Allowable maximum overload protection current 1000A RMS Basic Functio...

Page 11: ...00Hz Active Energy 0 001 9999 kWh 3 2 digits Temperature 50O C 1300O C 58O F 2372O F Special Functions Auto Ranging Single phase 2 wire Balance 3 phase 3 wire 3 phase 4 wire True RMS AC Voltage or Cur...

Page 12: ...y as soon as the battery indicator appears With a low battery the Meter might produce false readings that can lead to electric shock and personal injury 2 When opening the battery door must make sure...

Reviews: