background image

 

 

UMAX141520 Version 1B 

 

 

14-19 

 

4.  TECHNICAL SPECIFICATIONS 

4.1 Power Supply Input 

Table  2 Power Supply Input 

Power Supply Input - Nominal 

12V, 24Vdc nominal (9…36VDC power supply range) 

Protections  

Surge protection is provided. 
Reverse polarity protection up to -50V is provided. 
Input overvoltage (45V) and input undervoltage (6V) protection are 
provided. 
The unit is designed for 12Vdc based load dump. 

Power Consumption 

135 mA @ 12V; 70 mA@ 24V typical 

Power LED 

GREEN = Power ON 

4.2 Automotive Ethernet 

Table  3 Automotive Ethernet Parameters 

Port Type 

1 port 
100BASE-T1//1000BASE-T1 (IEEE 802.3 bw/bp compliant 
Automatic Polarity Correction 
Default configuration: Slave (Master mode is configurable via serial 
interface) 

PHY 

Marvell 88Q2112 (100BASE-T1//1000BASE-T1) 

LED’s 

2 GREEN LEDs for Automotive Ethernet 
Automotive Ethernet LEDs: 

 

ON 

BLINK 

OFF 

LED [0]: Link 

Link 

 

No Link 

LED [1]: Activity 

 

Activity 

No Activity 

 

Activity:  
        Receive/Transmit 

Protection 

ESD protection for signal lines 

Protocol 

Automotive Ethernet  
Ethernet IEEE 802.3bw for 100BASE-T1 
Ethernet IEEE 802.3bp for 1000BASE-T1 

4.3 Ethernet 

Table  4 Ethernet Parameters 

Port Type 

1 port 
100BASE-TX/1000BASE-T (IEEE 802.3 compliant) 
Auto-Negotiation  
Automatic Polarity Correction  

MDIX 

Auto-MDI/MDIX (crossover) 

PHY 

Marvell 88EA1512 (100BASE-TX/1000BASE-T) 

Summary of Contents for AX141520

Page 1: ...User Manual UMAX141520 Version 1B Firmware 1 00 Automotive Ethernet to Ethernet Converter USER MANUAL P N AX141520...

Page 2: ...e Configuration Parameters 9 3 3 Set Default Configuration Parameters 10 3 4 Erase EEPROM 10 3 5 Temperature of Ethernet PHYs 10 3 6 Start Stop Logs 11 3 7 Reboot the Controller 11 3 8 Activate bootlo...

Page 3: ...Ethernet communicate at a speed of 1000Mbps and the Automotive Ethernet is configured to work in Slave mode Status LEDs provide information on Power Connection Link and Activity Power LED will be ON...

Page 4: ...535 Figure 2 M12 8 pin Ethernet Connector with RJ45 2 2 M12 12 pin The M12 12 pin connector is used for power supply RS 232 CAN and Automotive Ethernet 1 Phoenix Contact M12 12 pin connector A coded T...

Page 5: ...serial terminals Tera Term Serial Port setup is shown below Figure 3 Tera Term Serial port setup Default configuration menu includes Project details like Project Name Version number Release Date Part...

Page 6: ...UMAX141520 Version 1B 6 19 Figure 4 Default Tera Term Menu...

Page 7: ...UMAX141520 Version 1B 7 19 To view or change the configuration please enter the password AX141520 Figure 5 One time password to access the Menu...

Page 8: ...PHY is configured to work as Master If the converter Mode is Slave it shows that Automotive Ethernet PHY is configured to work as Slave Speed shows the speed of both PHYs Log Timing is used to see the...

Page 9: ...the converter is expecting for the string Speed Changing the Speed will change the Speed of both Ethernet and Automotive Ethernet PHYs Type Mode to change the mode Press 1 to configure the Automotive...

Page 10: ...converter will have the last configured Speed Mode and Log Timing 3 4 Erase EEPROM Press 9 to Erase EEPROM Erasing the EEPROM will erase the Firmware Flags and Firmware Configurations Mode Slave and L...

Page 11: ...nverter This will simply restart the converter Rebooting the converter will not change the Mode or Speed of the converter This option is useful to restart the converter through Tera Term 3 8 Activate...

Page 12: ...s received from Axiomatic Technologies to reflash Bootloader flags will be erased Which shows that firmware is erased Ready to flash new firmware Yes No Enter Yes or No and press enter Use Menu File S...

Page 13: ...UMAX141520 Version 1B 13 19 Figure 11 Step 1 File Send File Figure 12 Select Binary and Select the Firmware File...

Page 14: ...rt 100BASE T1 1000BASE T1 IEEE 802 3 bw bp compliant Automatic Polarity Correction Default configuration Slave Master mode is configurable via serial interface PHY Marvell 88Q2112 100BASE T1 1000BASE...

Page 15: ...cifications Table 6 General Specifications Functionality Model AX141520 can be configured to acts as a master or a slave Microprocessor STM32F413CGU6 Compliance CE marking pending Vibration Random Vib...

Page 16: ...UMAX141520 Version 1B 16 19 4 6 Housing Figure 13 Dimensional Drawing...

Page 17: ...6117 Connector J1 on the right hand side PIN Description 1 BI_DC_P 2 BI_DD_P 3 BI_DD_N 4 BI_DA_N 5 BI_DB_P 6 BI_DA_P 7 BI_DC_N 8 BI_DB_N Mating Connectors Mating connectors should meet the following s...

Page 18: ...UMAX141520 Version 1B 18 19 Figure 14 AX070535 Mating Cable Figure 15 AX07533 Mating Cable...

Page 19: ...8th 2021 Meera Patel Initial Draft 1 0 February 4th 2022 Meera Patel Completed the User Manual 1A February 4th 2022 Meera Patel Updated the Firmware Reflashing interface 1B September 7 2022 Amanda Wi...

Page 20: ...orders and should verify that such information is current and complete Users should satisfy themselves that the product is suitable for use in the intended application All our products carry a limite...

Reviews: