3.3 Set Default Configuration Parameters
Press ‘3’ to set the default configuration parameters. This option will set the Mode and Speed to Slave and
1000Mbps respectively, as the default mode is Slave mode and default speed is 1000 Mbps.
The log timing will be also changed to the default value, which is 1 Second.
The configuration settings will be saved. So, after reset or power cycle, the converter will have the last
configured Speed, Mode, and Log Timing.
3.4 Erase EEPROM
Press ‘9’ to Erase EEPROM. Erasing the EEPROM will erase the Firmware Flags and Firmware
Configurations (Mode/Slave and Log Timing) stored in EEPROM. So, in the next power cycle, the firmware
will store default Configuration parameters and Firmware Flags.
This is useful while doing the Firmware Version update, to erase the old version number stored in EEPROM
and save the new version number.
3.5 Temperature of Ethernet PHYs
Press ‘c’.to read the internal temperature of both the PHYs in Celsius.
Figure 8 Temperature of PHYs in Fahrenheit