UM AX032200 Version 1.0 37-46
3.11. Set-Reset Latch Block
The Set-Reset Latch Block setpoints are defined in Section 1.12. Refer to that section for detailed
information on how these setpoints are used. The screen capture in Figure 15 displays the
available setpoints for each of the Set-Reset Latch Blocks. The table below the screen capture
highlights the allowable ranges for each setpoint.
Figure 15: Screen Capture of Set-Reset Latch Block Setpoints
Name
Range
Default
Notes
Block Enabled
Drop List
False
Reset Source
Drop List
Control Not Used
Refer to Table 1
Reset Number
Depends on Source Selected
1
Refer to Table 1
Reset Minimum Threshold
Drop List
0%
Refer to Section 1.12
Reset Maximum Threshold
Depends on Source Selected
100%
Refer to Section 1.12
Set Source
Drop List
Control Not Used
Refer to Table 1
Set Number
Drop List
1
Refer to Table 1
Set Minimum Threshold
Depends on Source Selected
0%
Refer to Section 1.12
Set Maximum Threshold
Drop List
100%
Refer to Section 1.12
Table 27: Default Set-Reset Latch Block Setpoints