UM AX032200 Version 1.0 29-46
Figure 9: Screen Capture of Default Diagnostic Setpoints
Name
Range
Default
Notes
Event Generates a DTC in DM1
Drop List
False
Refer to Section 1.6
Event Cleared Only by DM11
Drop List
False
Refer to Section 1.6
Lamp Set by Event in DM1
Drop List
Amber, Warning
Refer to Section 1.6
SPN for Event used in DTC
0...524,287
520704
Refer to Section 1.6
FMI for Event used in DTC
Drop List
Voltage Below Normal, Or
Shorted to Low Source
Refer to Table 9
Delay Before Sending DM1
0…84,600,000
1000
Units in [milliseconds]
Delay Before Clearing DM1
0…84,600,000
0
If digital output OFF after
this time, a DTC will not be
sent on a DM1 message
anymore.
Table 22: Default Diagnostic Setpoints
3.6. Constant Data List Setpoints
The Constant Data List function block is provided to allow the user to select values as desired for
various logic block functions. The function block provides two pre-set (for 0 and 1) and four
constant signals. The four constants are fully user configurable to any value b/-
1,000,000. The default values are displayed in the screen capture below.
Figure 10: Screen Capture of Constant Data Setpoints