1 - Range
2 - Accuracy
3- Resolution
Input resistance: 10M. Frequency response: 40~400Hz. Display: Mean value response(Sine virtual value).
Overload protection :1000V DC or 750V AC peak value.
Note
• Do not measure the DCV above 1000V or ACV above 750V.
• When high voltage is measured, be sure to avoid electric shock. After measurement, immediately
disconnect the test probe and the tested circuit.
8.2.3. Resistance measurement
• Turn the function/range SELECT switch “Ω
” gear.
• Respectively insert the red test probe and black test probe into the V and COM ends.
• Connect the test probe cables to the tested resistor as shown, so the resistance value displays on the
LCD .
Note
• At 200Ω range,it should make the test leads short to measure the wire resistance,then ,subtracts from
the real measurement.
• If the tested resistor is open or its resistance is out of the max. range of the clamp multimeter, it will
show “OL”.
• Do not input any voltage when measure resistance.
Resistance (Ω)Technical Indicators: