background image

SES 556-09 | SES 556-19
Unicable multiswitch 

Operation Instructions

State of the art 2015-03-20 - Reserving change in design and type - 
We cannot be held liable for printing errors

Manufacturer
AXING AG 
Gewerbehaus Moskau
CH-8262 Ramsen 

EWR contact adress
Bechler GmbH
Am Rebberg 44
D-78239 Rielasingen

Safety advice:

4

Installation and repairs to the equipment may only be carried out by 
technicians observing the current VDE guidelines. No liability will be 
assumed in the case of faulty installation and commissioning.

4

Before opening the equipment pull out the power plug or remove the 
power supply, otherwise there is danger of electrocution. This is also 
valid for cleaning the equipment or working on the connections. 

4

Only use the mains cable connected to the device. Never replace any 
parts or make any modifications on the mains cable. Otherwise there is a 
risk of mortal injury for which we cannot be held liable.

4

Providing that a serviceable fuse exists, the power plug must be pulled 
out before changing the fuse. Defective fuses may only be replaced with 
standard compliant fuses that have the same nominal value.

4

The equipment may only be operated in dry rooms. In humid rooms or 
outdoors there is danger of short-circuit (caution: risk of fire) or 
electrocution.

4

To prevent damage to your equipment and to avoid possible peripheral 
damages, the devices foreseen for wall mounting may only be installed 
on a flat surface.

4

Choose the location of installation or mounting so that the power plug 
can be reached and pulled out of the socket easily in case of danger. 
Choose the location of installation or mounting such that children may 
not play unsupervised near the equipment and its connections. The 
location of installation or mounting must allow a safe installation of all 
cables connected. The mains cable as well as feeder lines may not be 
damaged or clamped by objects of any kind. 

4

Choose the location of installation or mounting so that under no 
circumstances liquids or objects can get into the equipment (e.g. 
condensation, water coming from leaking roofs or flowing water, etc.).

4

Avoid exposure of the equipment to direct sunlight and to other heat 
sources (e. g. radiators. other electrical devices, chimney, etc.). Devices 
that are equipped with heat sinks or ventilation slots must under no 
circum-stances be covered or blocked. Also ensure for a generous air 
circulation around the equipment. In this way you avoid possible 
damage to the equipment as well as a risk of fire caused by overheating. 
Absolutely avoid that cables come near any source of heat (e.g. 
radioators, other electrical devices, chimney, etc.).

Technical specifications:

 

 

SES 556-09/-19

Inputs
SAT 

 

4

terrestrial 

 

1

Subscriber ports 

 

1

Trunk outputs 

 

5

Frequenzy range
terrestrial 

 

5...862 MHz

SAT 

 

950...2200 MHz

Transmission frequencies 

 

1280 MHz

 

 

1382 MHz

 

 

1484 MHz

 

 

1586 MHz

 

 

1688 MHz

 

 

1790 MHz

Tap loss terrestrial 

 

13 dB

Gain
Trunk terrestrial

 dB

 

 

-2,5

Trunk SAT 

 

-1,5

 dB

Output level 

Subscriber ports

 

 

88 dBµV*

LNB supply 

 

14 V/18 V/ 22 kHz

Current consumption 

 

300 mA

*For an input level of 60...90 dBµV

WEEE Nr. 

DE14023300

Your device is marked with the WEEE symbol (Waste Electronics 
and Electrical Equipment). This means that the electrical and 
electronic components must not be disposed of as residual waste. 
Used electrical and electronic components must be disposed of 
separately.