Notes on support for OpManager and Paessler PRTG Network Monitor
When adding a device, check that the credentials ("password") has been used.
By default, the MIE supports the "SNMP v1/v2 Public" profile (community name "public").
The following SNMP settings must be changed to also display the CPU load:
Select Axing Device
→
Settings
Scroll down to "SNMP Compatibility Options".
Disable "Inherit from".
Change the Walk Mode value to: "Use GETNEXT requests".
Click Save.
4.8.
LOGS
4.8.1.
Log entries
Under LOGS you can see the log entries of the headend.
•
The system log is written to the flash memory, so it is still available after rebooting the headend.
•
The status log is written to RAM and is empty after rebooting the headend.
Choose
Statuslog
.
The entries of the status log are displayed.
Choose
Systemlog
.
The entries of the system log are displayed.
Click SAVE LOG to save the respective log entries as a txt file.
Click on ERASE LOG to delete the respective log entries.
4.9.
Licenses for Software Extensions
Software extensions can be used to extend the functions of a headend. You require a license for a software extension.
4.9.1.
Purchase licenses
You can purchase a license by ordering the appropriate software extension from AXING. When ordering, you must provide the
serial number of the headend. A license file will be generated for you to match exactly this serial number. Important: The license is
bound to the serial number and is not transferable to other devices!