Commissioning / Initial Start-Up
Initial Test Procedures
With breaker and power turned on, and pump running, check all alarms for proper operation:
1.
Slowly partially close inlet ball valve. At 12” HG pump should turn off and red indicator light “HIGH VACUUM” will
illuminate. Open inlet ball valve again. Reset alarm by pushing the “RESET ALARM” button.
2.
Slowly partially close outlet ball valve. At 15 PSI pump should turn off and the red indicator light “HIGH PRESSURE” will
illuminate. Open outlet ball valve again. Reset alarm by pushing the “RESET ALARM” button.
Note: If any of the above described alarm test procedures fail or if any alarm trip value deviates, immediately contact AXI
International.