31
TECHNICAL DATA
ITEM
DESCRIPTION
Nominal voltage
120 V~, 60 Hz
Power consumption ( max. )
1100W
Protection degree
IPX4
Cable length
1.1 m ( 435/16 inches )
Recommended pressure range
(bidet portion only)
0.21 - 0.55 MPa ( 30 - 80 psi )
Minimum and Maximum pres-
sure (bidet portion only)
0.14- 0.69 MPa ( 20 - 100 psi )
Operating pressure (toilet)
Refer to cistern specifications
Ambient temperature range
4 - 40 °C ( +39 to +104 °F )
Water temperature range
4 - 35 °C ( +39 to +95 °F )
Product weight
29 kg ( 64lbs )
Product dimension ( L × B × H ) 798 × 584 × 498 mm ( 313/7×193/5×23 inches )
Maximum load (Seat and lid)
150kg ( 330lbs )
Max. flow rate rear wash
5 levels 0.35 L/min ( 1/16 gal/min )
Max. flow rate front wash
5 levels 0.35 L/min ( 1/16 gal/min )
Spray arm position
5 levels
Water temperature
5 levels 31 - 39 °C ( +88 to +102 °F )
Air dryer temperature
5 levels 30 - 50 °C ( +86 to +122 °F )
Seat temperature
5 levels 29 - 37 °C ( +84 to +98 °F )
TECHNICAL SUPPORT
For any questions or any assistance with this product, please contact your dealer or call us at
1-800-769-4857
[email protected]
www.axentbath.us
LEGAL DIRECTIONS
This manual contains important information on the intended use, correct operation and proper main-
tenance of the equipment. Knowledge of and compliance with the instructions of this manual are pro-
vided for both the safe use of the equipment and for the safety of its operation and maintenance. In this
manual, not all kinds of applications and improper manipulations are considered. In addition, attention
is drawn to the following: The content of these instructions is neither part of any previous or existing
agreement, commitment or legal relationship, nor does it change from an existing agreement, com-
mitment or legal relationship. Any commitment by AXENT results from the respective warranty. These
include the complete and authoritative warranty obligation AXENT. The statements in this manual do
not constitute an extension or a restriction of the claims under the warranty provisions. This manual is
protected by copyright. Copies and / or translations into other languages may be made only with prior
written approval of AXENT.
Summary of Contents for AXENT.ONE PLUS
Page 1: ...USER MANUAL AXENT ONE PLUS...
Page 2: ......
Page 13: ...11 OPERATION WITH MAIN OPERATION DIAGRAM QUICK START ONE ONE REGULAR USE ONE ONE...
Page 35: ......