Frequency Generator /Upconverter Module Interface
Power Amplifier Module Interface
Signal Name
Backplane
Backplane
Signal Type
Description
PA Pin
Amplifier Interlock
J19-1A
J23-1
Discrete Contact Closure Input
Provides a pull down to the control and monitor
ing board to indicate the power amplifier module
is installed. Loe indicates the module is installed.
Reflected Power Metering
J19-32
J23-7
Analog Input 0-1.25V
Indicates the reflected power from the power
amplifier module. The scale factor for the
reflected power meterimg is 100%
Overtemperature Fault
J19-31B
J25-3
Discrete Contact Closure Input
Indicates an overtemperature condition exists in
the power amplifier module. A contact closure
(low) indicates a fault condition exists.
O/P Amplifier Status
J19-30B
J25-2
Discrete Open Collector Input
Indicates the operating status of the O/P amplifier
A pulled down low indicates that current is
flowing in all five transistors in the power
amplifier.
-5V Bias Sense
J19-29B
J25-1
Analog Input 0 to -6V
Indicates voltage level of the -5V bias supply.
There is a 1:1 relationship between this voltage
and the -5V bias supply.
48
Signal Name
Backplane
Backplane
Signal Type
Description
U/C Pin
External Ref Indicator
J19-4A
J21-26C Discrete Open Collector Input
High indicates prescence of a 10MHz reference
Logic Enable
J19-5A
J21-25C Discrete CMOS Output
Provides a load enable signal to PLL in the freq
synthesizer chip. A transition from low to high
loads data stored into synthesizer latches.
Data
J19-6A
J21-24C Discrete CMOS Output
Provides serial data to the freq synthesizer chip.
Works in conjunction with the clock output to
synchronously transfer data.
Clock
J19-7A
J21-23C Discrete CMOS Output
Provides serial clock to the freq synthesizer chip.
A rising edge on this clock transfers data into the
freq synthesizer chip.
AFC
J19-8A
J21-22C Analog Input 0-10V
Indicates level of AFC in the freq gen upconverter
Freq Gen U/C Interlock
J19-9A
J21-21C Discrete Contact closure input
Provides a pull down to indicate the freq gen
module is installed. Low indicates it is installed.
Unlock Indicate
J19-10A
J21-8C
Discrete Open Collector Input
Indicates the freq/upconverter module is locked
on the external or onternal 10Mhz reference. A
low indicates the module is unlocked.
Summary of Contents for 5720 Series
Page 1: ......
Page 11: ......
Page 12: ......
Page 13: ......
Page 14: ......
Page 20: ......
Page 27: ......
Page 31: ...Video Jumpers 27 J9 J11 Group delay enable Video loss fault enable 2 3 1 2 ...
Page 33: ...Back view of the Power Supply Module 29 ...
Page 38: ...LO Upconverter Module LO Sample SMA connector RF Output SMA connector Sample SMA connector 34 ...
Page 56: ......
Page 57: ......
Page 58: ......
Page 59: ......