7-22
PIM-P Analyzer User’s Manual
Copyright AWT-Global, LLC. All rights reserved.
7.3.2.2
REC Interval
PIM-P Analyzers record measurements whenever the
Record button is pushed. Multiple pushes create multiple,
corresponding individual log files. If measurements need
to be analyzed over a longer of time, PIM-P Analyzers can
record log data automatically by setting the REC interval
to a value other than “OFF”, which will record data
automatically at the interval entered. When RF power is
activated in the Field mode screen pressing the Record once starts recording, the
second push stops recording. The Status Indicator field will show the REC symbol
lit during recording. If RF power is switched off during recording, data logging
stops.
REC Intervals: 1s, 2s, 5s, 10s, 20s, 30s, 1m, 2m, 5m, 10m, 15m, 30m,
1h, 2h, 5h, 12h, 24h and “OFF”,
Default: OFF
7.3.2.3
Filter BW
Advanced Mode Only.
Default filter bandwidth of the PIM-P receiver is 1.2 kHz;
which is the optimized setting for best performance. Increasing
bandwidth opens the receiver, allowing to “see” if signals are
present close to the receiving signal frequencies. If Change of
Filter Bandwidth effects all IM frequencies that fall in the
receiving range of the PIM-P. Decreasing the filter bandwidth allows to eliminate
unwanted signals very close to the receiving signal frequencies. Possible Filter BW
settings are:
Filer BW: 300Hz, 600Hz, 1.2kHz, 2.4kHz,5kHz,10kHz, 12kHz, 15kHz ,25kHz
50kHz
Default:1.2 KHz
Note: Varying filter bandwidth influences the amount of RF energy measured by the
PIM-P receiver.
Wider Filter BW measurement values increase (lower negative number),
Tighter Filter BW measurement values decrease (higher negative numbers).
Summary of Contents for PIM-P
Page 4: ...1 1 PIM P Analyzer User s Manual Copyright AWT Global LLC All rights reserved INTRODUCTION 1...
Page 6: ...2 1 PIM P Analyzer User s Manual Copyright AWT Global LLC All rights reserved SAFETY SUMMARY 2...
Page 10: ...3 1 PIM P Analyzer User s Manual Copyright AWT Global LLC All rights reserved PIM P ELEMENTS 3...
Page 13: ...4 1 PIM P Analyzer User s Manual Copyright AWT Global LLC All rights reserved PRECAUTIONS 4...
Page 78: ...9 1 PIM P Analyzer User s Manual Copyright AWT Global LLC All rights reserved Pull Down Menu 9...
Page 85: ...10 1 PIM P Analyzer User s Manual Copyright AWT Global LLC All rights reserved What is PIM 10...
Page 92: ...12 1 PIM P Analyzer User s Manual Copyright AWT Global LLC All rights reserved Maintenance 12...
Page 100: ...13 1 PIM P Analyzer User s Manual Copyright AWT Global LLC All rights reserved Accessories 13...
Page 102: ...i PIM P Analyzer User s Manual Copyright AWT Global LLC All rights reserved Appendix...
Page 108: ...vii PIM P Analyzer User s Manual Copyright AWT Global LLC All rights reserved Lid Release...
Page 109: ...viii PIM P Analyzer User s Manual Copyright AWT Global LLC All rights reserved Foot...