7-6
PIM-P Analyzer User’s Manual
Copyright AWT-Global, LLC. All rights reserved.
H
Status Indicator Field
Shows status and activities of PIMM31:
ALC – Automatic Level Control
AUD – Audio On
REC –Data Recording
SPU – Soft Power
I
RSSI
RSSI (Received Signal Strength Indication) in dBm. External
signals at the receiving frequency / frequencies may disturb
PIM measurements.
For accurate PIM measurements RSSI should always be
below -130dBm.
J
PIM Value dBc
Measured PIM value numerically in dBc.
The unit dBc describes a measurement relative to the
carriers, in this case the carrier signals transmitted by the test
system.
Displays last value after RF power is turned off
K
Voltage Warning
Warning Sign appears when RF Power is switched on.
Voltage at the RF-port can reach up to 50V.
L
Bar Graph PIM
indicator
Graphical display of PIM measurement. Range is:
-175dBc (start green bar) to -110dBc (end red bar).
Default threshold green/red is -153dBc.
See System Menu for further information.
M
Display fields (3)
Site, Feeder, Sector
Detailed Information of selected Site (e.g. Base Station
Location), and Site specific information like Feeder line and
antenna sector.
Also often used to describe test setup, e.g. “Site:
20W_Combiner_Test”.
N
RF On / Off Switch
One Push switched RF ON, Second push switches RF ON.
The button is only active if Carrier parameters have been set
and Site information is available. For further information see
menus: Carrier Select and Site Select
O
RF Indicator light
Indicates when RF-power is ON
P
System
Opens System menu.
See Chapter System Menu for further information
Q
Audio On/Off
Audio Signal when measurement passes green/red threshold
of Bar Graph
R
Analyzer
Opens Analyzer Menu
For more information see chapter Analyzer Mode.
S
EXIT
Triggers Power down sequence.
Active only when RF-power is OFF.
T
Record
In single mode (default), log measurement and system data
of current measurement.
In auto mode, start/stop for recording continuous log
sequences.
For further information on recorded data and auto mode see
chapters Data and System Menu.
U
Carrier
Opens Carrier Select screen.
For more information see chapter Carrier Select:
Active only when RF-Power is OFF.
V
Site
Opens Site Select screen.
For more information see chapter Site Carrier:
Active only when RF-Power is OFF.
Summary of Contents for PIM-P
Page 4: ...1 1 PIM P Analyzer User s Manual Copyright AWT Global LLC All rights reserved INTRODUCTION 1...
Page 6: ...2 1 PIM P Analyzer User s Manual Copyright AWT Global LLC All rights reserved SAFETY SUMMARY 2...
Page 10: ...3 1 PIM P Analyzer User s Manual Copyright AWT Global LLC All rights reserved PIM P ELEMENTS 3...
Page 13: ...4 1 PIM P Analyzer User s Manual Copyright AWT Global LLC All rights reserved PRECAUTIONS 4...
Page 78: ...9 1 PIM P Analyzer User s Manual Copyright AWT Global LLC All rights reserved Pull Down Menu 9...
Page 85: ...10 1 PIM P Analyzer User s Manual Copyright AWT Global LLC All rights reserved What is PIM 10...
Page 92: ...12 1 PIM P Analyzer User s Manual Copyright AWT Global LLC All rights reserved Maintenance 12...
Page 100: ...13 1 PIM P Analyzer User s Manual Copyright AWT Global LLC All rights reserved Accessories 13...
Page 102: ...i PIM P Analyzer User s Manual Copyright AWT Global LLC All rights reserved Appendix...
Page 108: ...vii PIM P Analyzer User s Manual Copyright AWT Global LLC All rights reserved Lid Release...
Page 109: ...viii PIM P Analyzer User s Manual Copyright AWT Global LLC All rights reserved Foot...