2. Set the oscilloscope to trigger externally with the vertical setting at 50 Volts/div
and the horizontal setting at 1 us/div. Be sure that your oscilloscope and probe
setup can handle the maximum amplitude of 250V.
3. Turn on the AVOZ-E3-B. The main menu will appear on the LCD.
4. To set the AVOZ-E3-B to trigger from the internal clock at a PRF of 10 Hz:
a) The arrow pointer should be pointing at the frequency menu item. If it is not,
press the MOVE button until it is.
b) Press the CHANGE button. The frequency submenu will appear. Rotate the
ADJUST knob until the frequency is set at 10 Hz.
c) The arrow pointer should be pointing at the “Internal” choice. If it is not, press
MOVE until it is.
d) Press CHANGE to return to the main menu.
5. To set the delay to 1 us:
a) Press the MOVE button until the arrow pointer is pointing at the delay menu
item.
b) Press the CHANGE button. The delay submenu will appear. Rotate the
ADJUST knob until the delay is set at 1 us.
c) The arrow pointer should be pointing at the “Normal” choice. If it is not, press
MOVE until it is.
d) Press CHANGE to return to the main menu.
6. To set the pulse width to 5 us:
a) Press the MOVE button until the arrow pointer is pointing at the pulse width
menu item.
b) Press the CHANGE button. The pulse width submenu will appear. Rotate the
ADJUST knob until the pulse width is set at 5 us.
c) The arrow pointer should be pointing at the “Normal” choice. If it is not, press
MOVE until it is.
d) Press CHANGE to return to the main menu.
31
Summary of Contents for AVOZ-E3-B
Page 38: ...WIRING DIAGRAMS WIRING OF AC POWER...
Page 39: ...PCB 158R6 LOW VOLTAGE POWER SUPPLY...
Page 41: ...PCB 235D HIGH VOLTAGE DC POWER SUPPLY...
Page 42: ...PCB 197K HIGH VOLTAGE DISCHARGE CIRCUIT...
Page 43: ...PCB 104G KEYPAD DISPLAY BOARD...
Page 44: ...MAIN WIRING POSITIVE UNITS...
Page 45: ...PERFORMANCE CHECK SHEET 45...