PUTTING MAGIC TBR INTO OPERATION
13
2
PUTTING MAGIC TBR INTO OPERATION
2.1
Mounting
With its dimensions (W
×
H
×
D) of 440 mm
×
44,5 mm (1 U)
×
273 mm
the
MAGIC
TBR
system can be used either as desktop device or mounted in 19-inch racks.
Corresponding 19“mounting brackets are included in delivery.
When mounting the unit please keep in mind that the bending radius of the
connected cables is always greater than the minimum allowed value.
Although
MAGIC TBR
has an integrated fan for proper cooling, it is recommended
to have sufficient ventilation. The ambient temperature of the system should be
within the range of +5
°
C and +45
°
C. This threshold is specially to observe if the
system is inserted in a rack.
The temperature of the system can be displayed via the front panel under
MENU >
STATUS INFORMATION or via the System Monitor of the web interface.
During operation humidity must range between 5% and 85%.
Incorrect ambient temperature and humidity can cause functional deficiencies.
Operation outside the threshold values indicated above leads to a loss of warranty
claim.
2.2
Connection to the main voltage
The system can be operated with main voltage in the range from 100 V to 220 V via
the integrated redundant power supplies. The line frequency can vary from 45 Hz
to 65 Hz. The maximum power consumption is not higher than 50 W if both
modules are equipped.
Summary of Contents for MAGIC TBR
Page 1: ...MAGIC TBR Tunnel Break In Rebroadcast System for DAB Hardware and Software Manual...
Page 2: ......
Page 4: ......
Page 12: ...INTRODUCTION 12...
Page 18: ...PUTTING MAGIC TBR INTO OPERATION 18...
Page 36: ......
Page 47: ......
Page 48: ...THE WEB INTERFACE OF MAGIC TBR 48...
Page 54: ...INTERFACES 54...
Page 58: ...58...
Page 60: ......
Page 64: ......
Page 66: ...INDEX 66 Test 22 Time 43 TTL 11 22 35 50 55 U Updates 59 Uptime 43 W Wiring 16 Y Year 37...