EXTENSION operating mode
This mode of operation allows the siren to be controlled by AVS control panel not developed for the control of the Serial siren
directly on RS485.
To use them, it is sufficient to enable an extension and make the following settings:
Additional relay n ° x, simulates the input + SA at the buzzer
Open Collector No. 1 satellite, simulates the input LED on the siren
Open Collector No. 2 satellite, simulates the input STC on the siren
The signals from the siren to the control panel, will be reported only if you will program the zone inputs as used and will have the
following mapping:
•
Extension
Zona 1
of the satellite: sum tamper (tamper reflects physical output)
•
Extension
Zona 2
del satellite: sum fault (output reflects physical fault)
•
Extension
Zona 3
del satellite: input tamper
•
Extension
Zona 4
del satellite: defoamers
•
Extension
Zona 5
del satellite: thermal probe
•
Extension
Zona 6
del satellite: vibration (accelerometer)
•
Extension
Zona 7
del satellite: No power supply from the control panel
•
Extension
Zona 8
del satellite: not used
•
Extension
Zona 9
del satellite: ruined bridge
•
Extension
Zona 10
del satellite: low battery
•
Extension
Zona 11
del satellite: faulty battery
•
Extension
Zona 12
del satellite: failure cone siren
•
Extension
Zona 13
del satellite: faulty flash
•
Extension
Zona 14
del satellite: faulty green LED
•
Extension
Zona 15
del satellite: faulty red LED
•
Extension
Zona 16
del satellite: faulty accelerometer
NOTE
: the conditions of “TAMPER” “low battery” and “battery missing” may be sent to the control panel in compatible mode with
traditional satellites, allowing you to avoid configuring virtual zones (Operating mode:1).
In this case, in the keyboard, the event memory etc., the control panel will show messages relating to an extension.
If this is not wanted, simply set the “operating mode” 2 and program zones to have alerts.