- 11 -
Technical Features
CITY (X) LED HP
CITY CARB.LED HP
TS85 P LED HP
TS85 V LED HP
TS85 X LED HP
Power supply
9.6 V = / 15 V =
Minimum operating voltage
9,5V
(battery charging not warrantied – not compliant with EN50131
requirements)
12,8V
(for correct battery charging - compliant with EN50131 requirements)
Low voltage threshold
10.5 V =
Rated supply voltage
13.8 V =
Max. consumption in charging from CP
400 mA
Consumption in alarm from CP
100 mA
Quiescent current
40 mA
Sound pressure level dB (A) at 3 meters
105 dB (A) - Depending on modulation
Siren frequency HZ
between 1300 and 1750
Allocable battery
12V - 2.3 Ah
Degree of protection
IP34
Operating temperature
between - 25°C and + 55°C
Container size (DXLXH) in mm
80 x 200 x 250
110 x 235 x 290
110 x 235 x 290
Weight in Kg
1.3
2.0
2.1
Performance level EN50131 - 4
GRADE 3 CLASS IV
Certification body
Telefication
Board
+SA / DB
RS485 Connection
STC / DA
RS485 Connection
-
Negative power supply
+
Power Positive and Siren Battery Recharge. 13.8 V power supply =
NOTE: when the rempote main drop, the siren start to sound.
S1
Not used
J1
Cone and Siren Battery connection connector
J2 - LED
LED and FLASH connection connector
J3 - FOAM
Optional Anti-foam connection connector -
S85
mode
J4 - TAMPER
Anti-removal system connection connector
PB1
Programming button
PB2
Programming button
OPTIONAL
T
T
TAMPER output with positive safety, with Contact Normally Closed, capacity 3 A - 24 V = Is
activated by the Anti-removal (Anti-opening and Anti-tearing) system connected to connector
J4, the Lack of Power supply from the control unit and from the Anti-foam, Anti-perforation and
Over temperature probes. The relay remains in alarm status as long as the cause generating
the activation persists. The Anti-foam, Anti-perforation and the Over temperature signals can be
deactivated through programming.
For the configuration refer to the FUNCTIONS TABLE.
B
Block Input. With positive present, the sound of the Cone is inhibited.
FA
Fault signalling output. It provides a transistorized negative, max. 50 mA, which is lost in the
case of malfunctioning of the Cone, Cone handling circuit, Flash, LEDs and if the Siren battery is
Low or Faulty. Loss of remote power source, loss integrity of trigger command interconnection.
LED
Not used
E
N
G
J 2 LE D
F OAM
J 3
P
B2
P
B1
J 1
S TC
DA
+S A
DB
LE D
F A
B
T
T
J 4
TAMP E R
S 1
RELE’
TAMPER