12. Route middle junction box to Control Unit cables
Wiring instructions-Power and Data Cable:
•
Connect the red positive CTRL + 24VDC conductor from the middle junction box to
circuit breaker 3 (i.e. Label L-810F + 24VDC) on terminal block 1 in the Control Unit
•
Connect the black negative CTRL -24VDC conductor from the middle junction box to
the ‘L-810F -24VDC’ labelled terminal on terminal block 1 in the Control Unit
•
Connect the orange CTRL Alarm COM conductor from the middle junction box to the
‘L-810F Alarm Common’ labelled terminal on terminal block 1 in the Control Unit
•
Connect the green CTRL Alarm NC Conductor from the middle junction box to the
‘L-810F Alarm Signal’ labelled terminal on terminal block 1 in the Control Unit
•
Connect the white PC conductor from the middle junction box to the ‘L-810F PC Input’
labelled terminal on terminal block 1 in the Control Unit