AV-OL-KT-A1 - Obstruction Light Kit
Installation & Service Manual
Latest products and information available at
www.avlite.com
23
4. Wire the Photocell to the Control unit and cut cable to the required length.
Wiring instructions-Power and Data Cable:
•
Connect the black positive conductor from the External Photocell to circuit breaker 5
(labelled ‘PC +24VDC’) on terminal block 1 in the Control Unit
•
Connect the white negative conductor from the External Photocell to the ‘PC
-Common’ labelled terminal on terminal block 1 in the Control Unit
•
Connect the green Photocell signal conductor to the ‘PC Signal’ labelled terminal on
terminal block 1 in the Control Unit
Refer to section
7.2.3 Cabling Requirements
for recommended cable sizes.