2. Using 18 AWG wires (red for + and black for -), wire the 12-24VDC input to +Out1- on the D8P board’s
terminal block.
ACM
Embedded
Controller
Tamper
(Input 5)
+
-
+
+
-
-
-
+
AC
Fail
(Input 6)
Batt
Fail
(Input 7)
+12-24VDC
IN
D8P
OUT
8
7
6
5
4
3
2
1
-
-
-
-
-
-
-
-
+
+
+
+
+
+
+
+
3. On the FPO75’s SYSFLT terminal block:
l
Wire C to Batt Fail + (22 AWG).
l
Wire NO to Batt Fail - (22 AWG).
ACM
Embedded
Controller
Tamper
(Input 5)
+
-
+
+
-
-
-
+
AC
Fail
(Input 6)
Batt
Fail
(Input 7)
+12-24VDC
IN
FPO75
SYS FLT
AC FLT
FAI INPUT
C
NC NO
C
NC NO
4. On the FPO75’s ACFLT terminal block:
l
Wire C to AC Fail + (22 AWG).
l
Wire NO to AC Fail - (22 AWG).
ACM
Embedded
Controller
Tamper
(Input 5)
+
-
+
+
-
-
-
+
AC
Fail
(Input 6)
Batt
Fail
(Input 7)
+12-24VDC
IN
FPO75
SYS FLT
AC FLT
FAI INPUT
C
NC NO
C
NC NO
Configure and Wire Data