![Avigilon 12C-H4A-4MH-360 Installation Manual Download Page 2](http://html1.mh-extra.com/html/avigilon/12c-h4a-4mh-360/12c-h4a-4mh-360_installation-manual_3031701002.webp)
Important Safety Information
This manual provides installation and operation information and precautions for the use of this device. Incorrect
installation could cause an unexpected fault. Before installing this equipment read this manual carefully. Please
provide this manual to the owner of the equipment for future reference.
This Warning symbol indicates the presence of dangerous voltage within and outside the product
enclosure that may result in a risk of electric shock, serious injury or death to persons if proper
precautions are not followed.
This Caution symbol alerts the user to the presence of hazards that may cause minor or moderate injury
to persons, damage to property or damage to the product itself if proper precautions are not followed.
WARNING —
Failure to observe the following instructions may result in severe injury or death.
l
Installation must be performed by qualified personnel only, and must conform to all local codes.
l
This product is intended to be supplied by a UL Listed Power Unit marked “Class 2” or “LPS” or “Limited
Power Source” with output rated:
l
With IR LEDs: 24 V AC ± 10%, 74 VA minimum, or 24 V DC ± 10%, 52 W minimum, or a Microsemi
PD9601G/AC (90 W) or Microsemi PD9501GR/AC (60 W) Power over Ethernet (PoE) mid-span
injector.
l
Without IR LEDs: 24 V AC ± 10%, 37 VA minimum, or 24 V DC ± 10%, 26 W minimum, or PoE+
IEEE802.3at Type 2 compliant Power Sourcing Equipment (PSE) rated 50-57 V DC, 25.5 W
minimum.
l
Any external power supply connected to this product may only be connected to another Avigilon
product of the same model series. External power connections must be properly insulated.
l
Do not connect directly to mains power for any reason.
CAUTION —
Failure to observe the following instructions may result in injury to persons or damage to
the device.
l
Do not install near any heat sources such as radiators, heat registers, stoves, or other sources of heat.
l
Do not subject the device cables to excessive stress, heavy loads or pinching.
l
Do not open or disassemble the device. There are no user serviceable parts.
l
Refer all device servicing to qualified personnel. Servicing may be required when the device has been
damaged (such as from a liquid spill or fallen objects), has been exposed to rain or moisture, does not
operate normally, or has been dropped.
l
Do not use strong or abrasive detergents when cleaning the device body.
l
Use only accessories recommended by Avigilon.
2