FlightMax EX5000
-40-
600-00105-000 Rev 01
Appendix - Lightning Messages
Lightning Messages
& Colors
Meaning
Recommended
Pilot Action
Lightning Sensor is
Operating Normally
Lightning source is operating in
a normal state from a
recoverable fault that was
previously acknowledged.
Acknowledge
Lightning Sensor is in
Noise- Monitor Mode
Lightning source is in
Noise- Monitor Mode.
Have maintenance check
configuration and
installation.
Lightning Sensor is in
Demo Mode
Lightning source is in Demo
Mode.
Have maintenance check
configuration and
installation.
Lightning Sensor is in
Test Mode
Lightning sensor in a self- test
mode.
Acknowledge
Lightning Sensor
ERROR
MFD receives a "recoverable
fault" notification.
Have maintenance check
configuration and
installation.
Lightning Sensor has
FAILED
MFD receives a "fatal fault"
notification.
Have maintenance check
configuration and
installation.
Lightning Sensor is Not
Communicating
MFD receiving no data from the
lightning sensor.
Have maintenance check
configuration and
installation.
Lightning Ahead
Stormscope is indicating
discharge activity horizontally
within ± 22 ° of the aircraft nose
and within 75nm.
Determine location of
lightning and avoid.
Lightning Heading
Source Failed
Stormscope is configured as a
heading source and a "fatal
heading fault" is received.
Have maintenance check
configuration and
installation.
Lightning Heading
Source OK
Stormscope is configured with
heading input.
Acknowledge
Lightning Antenna
Location Changed
Stormscope antenna location
disagrees with MFD setting.
Have maintenance check
configuration and
installation.