![Avidyne DFC90 Pilot'S Manual Download Page 82](http://html.mh-extra.com/html/avidyne/dfc90/dfc90_pilots-manual_3031511082.webp)
6-3
Limitations and Performance
PFD
Version
AP
Version*
Wired for
Flap
Position?
Operational Notes
Avidyne
8.0.6
or
8.0.5
or
8.0.4
2
No
No Flap Overspeed alert
Underspeed alerts in both
Envelope Protection and
Envelope Alerting use a
more conservative no-flap
speed value
No Envelope Alerting
Underspeed functionality
when AP is in standby (AP
Ready) state
Underspeed alerts are not
suppressed in the flare
and on rollout
Avidyne
8.0.6
or
8.0.5
or
8.0.4
1
Yes or No
No Envelope Alerting
functionality
No Excessive Bank alert
DFC90 will disconnect
during any AHRS-TC
Miscompare
DFC90 has tighter
engagement limits
No Flap Overspeed alert
Underspeed alert uses a
more conservative no-flap
speed value
Underspeed alerts are not
suppressed in the flare
and on rollout
(cont. on next page)
Limitations and Performance 6-3
Change 3