Abnormal Procedures
5-23
MSR FAIL
Failure Indication:
If the autopilot computer determines that it can no longer read
from, or write to the internal maintenance and safety recorder, a
yellow “
MSR FAIL
” message is displayed on the PFD. In addition,
all aurals associated with the autopilot (e.g. full-time envelope
alerting, envelope protection alerts), will be absent.
Functionality Lost:
The autopilot will still be fully functional in all pilot-usable modes
but the on-board data logging has likely stopped and all autopilot
aural alerts will be unavailable.
Recommended Pilot Action:
Apply extra vigilance to the autopilot annunciator status
messages along the top of the PFD due to the absence of the
associated aural alerts.
After the flight, notify an Avidyne Service Center or Avidyne
Customer Support to coordinate for a repair action.
Change 3