Command
Function
Feedback
Example
/+[Y]/[X]:******.
Set communication between PC and
HDBaseT receiver.
①
Y is for RS232 port (connect with
RS232 port of HDBaseT receiver)
Y= 1~5 or A~H, The value of Y is
defined into the following meanings
(in a given baud rate depended by
the value of X):
a.
Y = 1~4, send this command to the
corresponding HDBaseT receiver
to control far-end device.
b.
Y = 5, send this command to all
HDBaseT receivers to control all
far-end devices.
c.
Y = A, B, C, or D
d.
Y = E, F, G, or H
For items c or d, send this
command, it will be saved to the
matrix switcher but taken without
action to corresponding HDBaseT
receiver. And its command
function will be effective almost at
the same time when you send the
command PWON (for item c) or
PWOFF (for item d).
Note:
A & E are for port 1. B & F are for
port 2.
C & G are for port 3. D & H are for
port 4.
②
X is for baud rate, its value ranges
from 1 to 7 (1--2400, 2--4800, 3--
9600, 4--19200, 5--38400, 6
—
57600, 7--115200)
③
***** is for data (max 48 Byte)
******
EDIDH[x]B[y].
Input port [y] learns the EDID from
output port [x].
If the EDID data is available and the
audio section supports not only PCM
mode, then force-set it to support PCM
mode only. If the EDID data is not
available, then set it to initial EDID
data.
EDIDH[x]B[y]
EDIDPCM[x].
Set the audio section of input port [x] to
PCM format in EDID database.
EDIDPCM[x]
EDIDG[x].
Get EDID data from output [x] and
display the output port number.
Hexadecimal EDID
data and carriage