AVG-CSK4K-44
Command
Function
Feedback Example
Out 2 1920x1080
Out 3 1920x1080
Out 4 1920x1080
%9977.
Check the status of digital audio for output
channels.
Out 1 2 3 4
Audio Y Y Y Y
%9978.
Check the HDCP compliance status of the
inputs.
In 01 02 03 04
HDCPEN Y Y Y Y
I-Lock[X].
Lock the channel [x], X=1~4
Channel[x] Lock!
I-Unlock[X].
Unlock the channel [x], X=1~4
Channel[x] Unlock!
A-Lock.
Lock all channels
A-UnLock.
Unlock all channels
Lock-Sta.
Check the lock status of all channels.
Channel 1->1 Lock!
Channel 1->2 Lock!
.....
Channel 2->1 Unlock!
.....
5.3 TCP/IP Control
Besides IR control and RS232 control, the Matrix Switcher boasts a TCP/IP port for
IP control.
Default settings: IP: 192.168.0.178; Subnet Mast: 255.255.255.0; Gateway:
192.168.0.1; Port: 4001.
The IP & gateway can be changed to suit network requirements, the Port cannot be
changed.
Connect the Ethernet port of the control device and the TCP/IP port of the Matrix
Switcher, and set same network subnet for the 2 devices, users are then able to
control the device via the web-based GUI or TCP/IP communication software.
5.3.1 Control Modes
The Matrix Switcher can be controlled by PC without Ethernet access or PC(s) within
a LAN.
Controlled by PC
Connect a computer to the TCP/IP port of the Matrix Switcher, and set its network
subnet to the same as the Matrix Switcher
’s
.