ZK840 Picklist Application User Instructions
35
6.2 DBASE key
Pick Start PrtFmt
This is the print format sent to the configured report printer when
the operator starts a picklist. Default format:
#CR#LF “RECIPE PICK LIST START” {A.180.1} #CR#LF
Pick Item PrtFmt
This is the print format sent to the configured report printer as the
operator steps from one fulfilled item to the next. The default
format:
“ITEM “{A.182.1} “VALUE” {A.185.1} {A.186.1} #CR #LF
Pick End PrtFmt
This is the print format sent to the configured report printer when
all items in the assembly have been fulfilled. The default format:
#CR #LF “RECIPE END STATUS “ {A.189.1} #CR #LF.
Assembly Totals
Select
ON
to increment the Sub and Grand total counters when an
assembly is complete.
Auto Tare
Setting is either true or false. When set to true, the scale will
automatically tare after each item in the assembly has been
fulfilled.
6.2 DBASE key
The screen in
appears when you press the
DBASE
key.
Figure 6.4 Database Select Action screen
This menu allows you to populate the available fields in the database. The default field
selection can be added to or changed using the PLU configuration. See
Each item is described below.