9
QC-3265 Checkweigher User’s Manual
The unit of measure annunciators are below the display and are reproduced
below. The lit annunciator tells you the currently selected unit of measure-
ment.
The center of zero annunciator, reproduced below, is next to the
ZERO
key.
When the annunciator is lit the scale is within ¼ division of zero.
Place the QC-3265 on a stable, level surface.
Use the leveling feet to level the scale. A bubble level is visible under the
scale platform shroud. Lock the feet in this position using the locknuts on the
feet.
Plug the unit into a properly grounded 115VAC outlet.
The socket-outlet must be installed near
the equipment and easily accessible.
There are two modes of operation for the QC-3265, the weight display mode
and the checkweigh mode.
• Use the weight display mode when you want to use the scale for
displaying weight. The scale powers up in weight display mode if there
is no target weight in memory.
• Use the checkweigh mode for checkweighing operations and the use
of the
OVER
,
ACCEPT
, and
UNDER
LEDs. If there is a target weight
in memory, the scale will power up in the checkweigh mode. Below are
explanations of the operation in each mode.
With the scale in weight display mode, follow these steps to perform a
weighment:
1.
Press the
ZERO
key to zero the
scale. . .
Display shows 0 weight.
2.
Place the object to be weighed on
the scale. . .
The weight is displayed.
Installation and Operation
Installation
There is no ON/OFF switch.
When the unit is plugged in it
will power up. If the battery
option is installed and enabled,
press any key to start.
Explanation of Modes
of Operation
Operation as a Scale
Press the
UNITS
key to view a
weight in a different unit of
measure.
The lb
and
oz annunciators will
be lit when you are in the LB-
OZ unit of measure. Two
numbers are displayed sepa-
rated by a space in LB-OZ.
The left number is the number
of pounds and the right is the
ounces to the correct division
size.